Dialyzer Reuse and Outcomes of High Flux Dialysis
Open Access
- 9 June 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (6) , e0129575
Abstract
The bulk of randomized trial evidence for the expanding use of High Flux (HF) hemodialysis worldwide comes from two randomized controlled trials, one of which (HEMODIALYSIS, HEMO) allowed, while the other (Membrane Outcomes Permeability, MPO) excluded, the reuse of membranes. It is not known whether dialyzer reuse has a differential impact on outcomes with HF vs low flyx (LF) dialyzers. Proportional Hazards Models and Joint Models for longitudinal measures and survival outcomes were used in HEMO to analyze the relationship between β2-microglobulin (β2M) concentration, flux, and reuse. Meta-analysis and regression techniques were used to synthesize the evidence for HF dialysis from HEMO and MPO. In HEMO, minimally reused (< 6 times) HF dialyzers were associated with a hazard ratio (HR) of 0.67 (95% confidence interval, 95%CI: 0.48–0.92, p = 0.015), 0.64 (95%CI: 0.44 – 0.95, p = 0.03), 0.61 (95%CI: 0.41 – 0.90, p = 0.012), 0.53 (95%CI: 0.28 – 1.02, p = 0.057) relative to minimally reused LF ones for all cause, cardiovascular, cardiac and infectious mortality respectively. These relationships reversed for extensively reused membranes (p for interaction between reuse and flux < 0.001, p = 0.005) for death from all cause and cardiovascular causes, while similar trends were noted for cardiac and infectious mortality (p of interaction between reuse and flux of 0.10 and 0.08 respectively). Reduction of β2M explained only 1/3 of the effect of minimally reused HF dialyzers on all cause mortality, while non-β2M related factors explained the apparent attenuation of the benefit with more extensively reused dialyzers. Meta-regression of HEMO and MPO estimated an adjusted HR of 0.63 (95% CI: 0.51–0.78) for non-reused HF dialyzers compared with non-reused LF membranes. This secondary analysis and synthesis of two large hemodialysis trials supports the widespread use of HF dialyzers in clinical hemodialysis over the last decade. A mechanistic understanding of the effects of HF dialysis and the reuse process on dialyzers may suggest novel biomarkers for uremic toxicity and may accelerate membrane technology innovations that will improve patient outcomes.Keywords
This publication has 96 references indexed in Scilit:
- ‘What’s in the NIDDK CDR?’—public query tools for the NIDDK central data repositoryDatabase: The Journal of Biological Databases and Curation, 2013
- Modifiable Risk Factors for Early Mortality on HemodialysisInternational Journal of Nephrology, 2012
- Effect of Online Hemodiafiltration on All-Cause Mortality and Cardiovascular OutcomesJournal of the American Society of Nephrology, 2012
- Dialyzer Reuse with Peracetic Acid Does Not Impact Patient MortalityClinical Journal of the American Society of Nephrology, 2011
- Abandoning Peracetic Acid-Based Dialyzer Reuse Is Associated with Improved SurvivalClinical Journal of the American Society of Nephrology, 2011
- The NIDDK Central Repository at 8 years--Ambition, Revision, Use and ImpactDatabase: The Journal of Biological Databases and Curation, 2011
- Role of Residual Kidney Function and Convective Volume on Change in β2-Microglobulin Levels in Hemodiafiltration PatientsClinical Journal of the American Society of Nephrology, 2010
- Considerations in the Statistical Analysis of Hemodialysis Patient SurvivalJournal of the American Society of Nephrology, 2009
- Effect of Membrane Permeability on Survival of Hemodialysis PatientsJournal of the American Society of Nephrology, 2009
- The Robust Inference for the Cox Proportional Hazards ModelJournal of the American Statistical Association, 1989