Abstract
Purpose: To report the initial safety and effectiveness profile for an anterior shape-changing, modular IOL, Juvene IOL (JIOL), for the treatment of aphakia and presbyopia after removal of the natural crystalline lens due to cataract. Setting: 2 private practices in Monterrey and Tijuana, Mexico. Design: Exploratory prospective multicenter open-label noncomparative clinical trial. Methods: A convenience sample of patients aged 50 to 80 years with planned cataract surgery was recruited to undergo unilateral or bilateral implantation with the JIOL. Patients were required to complete an informed consent and be able to dilate to at least 6.0 mm pharmacologically, be in good overall health, and have no significant eye health history to qualify. Visual acuities, defocus curves, and contrast sensitivity were measured for all patients 12 months postoperatively. Results: 51 of 58 eyes completed the 12-month visit. Intraoperative complication rates were extremely low (n = 1; missed base lens tab). The most frequent adverse events (AEs) were prolonged inflammation (N = 6) and cystoid macular edema (N = 4); all AEs were resolved without sequelae by the 12-month visit. The mean monocular logMAR corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity were 0.01, 0.08, and 0.24, respectively. Defocus testing showed visual acuity > 20/40 from approximately +1.00 through −2.00 diopters. Binocular implantation (n = 16) provided superior performance over monocular implantation. Conclusions: The JIOL offers a new solution to treat presbyopia, providing clear functional vision performance across a range of distances with an acceptable initial safety profile.Keywords
This publication has 22 references indexed in Scilit:
- Accommodative movements of the lens/capsule and the strand that extends between the posterior vitreous zonule insertion zone & the lens equator, in relation to the vitreous face and agingOphthalmic and Physiological Optics, 2015
- Rising Cataract Surgery Rates: Demand and SupplyOphthalmology, 2014
- Binocular Summation Improves Performance to Defocus-Induced BlurInvestigative Ophthalmology & Visual Science, 2011
- Four-Year Incidence and Progression of Diabetic Retinopathy and Macular Edema: The Los Angeles Latino Eye StudyAmerican Journal of Ophthalmology, 2010
- Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new conceptJournal of Cataract & Refractive Surgery, 2009
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Disability Glare in the Aging Eye. Assessment and Impact on Driving☆Journal of Optometry, 2009
- Cataract surgery on diabetic patients. A prospective evaluation of risk factors and complicationsActa Ophthalmologica Scandinavica, 2002
- Contrast sensitivity, acuity, and the perception of 'real-world' targets.British Journal of Ophthalmology, 1987
- Contrast sensitivity throughout adulthoodVision Research, 1983