Laser wavelength dependence of background fluorescence in Raman spectroscopic analysis of synovial fluid from symptomatic joints
- 1 July 2013
- journal article
- research article
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 44 (8) , 1089-1095
Abstract
Gout is a disease process where the nucleation and growth of crystals in the synovial fluid of joints elicit painful arthritis‐like symptoms. Raman spectroscopy is evolving as a potential diagnostic tool in identifying such crystals; however, attainment of sufficient Raman signal while overcoming the background fluorescence remains as a major challenge. The current study focused on assessing whether excitation in 532–700 nm range will provide greater signal intensity than the standard 785 nm while not being impeded by background fluorescence. We characterized the fluorescence spectra, absorption spectra and Raman spectra of synovial fluid from patients who presented ‘gout‐like symptoms’ (symptomatic) and controls (asymptomatic). A digestion and filtration method was developed to isolate crystals from synovial fluid while reducing the organic burden. Spectral profile and photobleaching dynamics during Raman spectroscopy were observed under an excitation wavelength range spanning 532 to 785 nm. Absorbance and fluorescence profiles indicated the digestion and filtration worked effectively to extract crystals from symptomatic synovial fluid without introducing additional fluorescence. Raman spectral analyses at 532 nm, 660 nm, 690 nm and 785 nm indicated that both asymptomatic and symptomatic samples had significant levels of fluorescence at excitation wavelengths below 700 nm, which either hindered the collection of Raman signal or necessitated prolonged durations of photobleaching. Raman‐based diagnostics were more feasible at the longest excitation wavelength of 785 nm without employing photobleaching. This study further demonstrated that a near‐infrared (NIR) OEM‐based lower‐cost Raman system at 785 nm excitation has sufficient sensitivity to identify crystals isolated from the synovial fluid. In conclusion, while lower excitation wavelengths provide greater signal, the fluorescence necessitates NIR wavelengths for Raman analysis of crystal species observed in synovial aspirates. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 28 references indexed in Scilit:
- Analysis of Crystals Leading to Joint Arthropathies by Raman Spectroscopy: Comparison with Compensated Polarized ImagingApplied Spectroscopy, 2009
- Raman spectroscopy of synovial fluid as a tool for diagnosing osteoarthritisJournal of Biomedical Optics, 2009
- Clinical Diagnostic Criteria for GoutJCR: Journal of Clinical Rheumatology, 2009
- Detection of calcium phosphate crystals in the joint fluid of patients with osteoarthritis – analytical approaches and challengesThe Analyst, 2008
- EULAR evidence based recommendations for gout. Part I: Diagnosis. Report of a task force of the standing committee for international clinical studies including therapeutics (ESCISIT)Annals of the Rheumatic Diseases, 2006
- Is photobleaching necessary for Raman imaging of bone tissue using a green laser?Biochimica et Biophysica Acta (BBA) - Biomembranes, 2006
- Effect of Hydrogen Peroxide Bleaching on Bone Mineral/Matrix RatioApplied Spectroscopy, 2002
- New Preparation Method of Bone Samples for Raman MicrospectrometryApplied Spectroscopy, 1998
- Identification of pathological mineral deposits by Raman microscopyThe Lancet, 1991
- Raman Spectroscopic Identification of Uric-Acid-Type Kidney StoneApplied Spectroscopy, 1990