Evaluation of an anatomical filter-based exposure equalization technique in mammography.
Authors:
- S SkiadopoulosSSS Skiadopoulos
- E SolomouESE Solomou
- C PierrakeasCPC Pierrakeas
- L CostaridouLCL Costaridou
- C P KalogeropoulouCKC P Kalogeropoulou
- J DimopoulosJDJ Dimopoulos
- 1 October 1998
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 71 (850) , 1049-1057
Abstract
An anatomical filter-based exposure equalization technique in mammography is clinically evaluated. An observer performance comparative study, between this technique and the conventional one, is carried out on the basis of the visualization of six anatomical features situated at the breast periphery. The effect of parenchymal breast patterns and compressed breast thickness in the visualization of these features is studied. 533 craniocaudal mammograms were interpreted by two radiologists independently, using a five-point rating scale. Use of the Wilcoxon ranking test for unpaired data shows statistically highly significant improvement (p < 0.0001) in the visualization of the nipple, areola, skin and subcutaneous fat in all cases, for the equalization technique. The improvement is dependent on parenchymal breast patterns and compressed breast thickness for peripheral Cooper's ligaments and peripheral surface veins. In the case of total fatty replacement and/or thin breasts neither technique seems to be superior (p > 0.05) with respect to these two features. Clinical results indicate the value of this technique in clinical routine.Keywords
This publication has 25 references indexed in Scilit:
- Practical application of a scan‐rotate equalization geometry to mammographyMedical Physics, 1996
- Analytical description of the high and low contrast behavior of a scan-rotate geometry for equalization mammographyMedical Physics, 1996
- A method for practical equalization mammography of the radiographically dense breast.RadioGraphics, 1995
- Rotary scanning equalization radiography: An efficient geometry for equalization mammographyMedical Physics, 1994
- Scanning equalization mammography: preliminary evaluation.RadioGraphics, 1994
- Observer performance and dose efficiency of mammographic scanning equalization radiographyMedical Physics, 1993
- Mammographic scanning equalization radiographyMedical Physics, 1993
- An anatomical filter for exposure equalization in mammographyEuropean Journal of Radiology, 1992
- Effects of x-ray beam equalization on mammographic imagingMedical Physics, 1990
- Exposure Equalization Technique in MammographyInvestigative Radiology, 1989