Background and objective: Contact force (CF) sensing is a novel technology used for catheter ablation of atrial fibrillation (AF). We compared the single procedure success of CF‐guided pulmonary vein isolation (PVI) with that of non‐CF guided PVI during a 3‐year (1,095 days) follow up period and analyzed the pattern of pulmonary vein (PV) reconnection.Methods: A cohort of 167 subjects (68 CF vs. 99 non‐CF) with paroxysmal AF were included in the study. Atrial arrhythmia (AA) recurrence was defined as documented AF, atrial flutter, or atrial tachycardia lasting >30 seconds and occurring after 90 days.Results: Subjects in the CF group showed a statistically nonsignificant improvement in AA free survival compared to those in the non‐CF group (66.2% vs. 51.5%; P value: 0.06). A greater propensity for reconnection was noted around the right‐sided PVs compared to left‐sided PVs related in both catheter ablation groups. For example, in the CF group 36% of right‐sided segments reconnected compared to 16% of left‐sided segments (P value <0.01).Conclusions: A greater propensity for reconnection was noted around the right sided PV segments in both the CF and non‐CF groups. The explanation for this finding was related to greater catheter instability around the right sided veins. Further research is needed to explore the utility of a “real‐time” composite indicator that includes RF energy, CF and catheter stability in predicting transmural lesion formation during catheter ablation.Keywords
Funding Information
- Canadian Institutes of Health Research
- University of Ottawa Heart Institute Foundation
- Biosense Webster
This publication has 25 references indexed in Scilit:
- Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial TreatmentCirculation: Arrhythmia and Electrophysiology, 2013
- The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA studyHeart Rhythm, 2012
- 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial DesignHeart Rhythm, 2012
- A novel radiofrequency ablation catheter using contact force sensing: Toccata studyHeart Rhythm, 2012
- Catheter Ablation for Atrial FibrillationJACC, 2011
- Long-Term Results of Catheter Ablation in Paroxysmal Atrial FibrillationCirculation, 2010
- Guidelines for the management of atrial fibrillation: The Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC)European Heart Journal, 2010
- Importance of Catheter Contact Force During Irrigated Radiofrequency Ablation: Evaluation in a Porcine Ex Vivo Model Using a Force‐Sensing CatheterJournal of Cardiovascular Electrophysiology, 2010
- A Systematic Review of Randomized Trials Comparing Radiofrequency Ablation with Antiarrhythmic Medications in Patients with Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2009
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008