Identification of two novel trace impurities in mobile phases prepared with commercial formic acid
- 8 November 2019
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 34 (5) , e8608
Abstract
Rationale: While liquid chromatography/high‐resolution mass spectrometry (LC/HRMS) is a versatile analytical technique, it is also sensitive to trace impurities. These impurities may come from a variety of sources, including reagents, solvents, and the sample matrix itself. Impurities in reagents may become concentrated and elute as peaks when a gradient method is used, and these peaks may cause suppression of peaks of interest both in the electrospray source, as well as in the C‐trap in systems that contain one. Methods: We observed a notable increase in the size of several impurity peaks in a reversed‐phase gradient method upon switching suppliers of formic acid. We used LC/HRMS to separate and fragment these impurity compounds and assign probable formulae. Results: The mass spectra were compared with those of compounds found in the literature with the same formulae, and the observed peaks were matched to two amine compounds not previously reported as impurities in LC/MS systems: trihexylamine and N ‐methyldihexylamine. The identities were confirmed by high‐resolution accurate mass and retention time matching against commercially available standards of these compounds. Conclusions: To the best of our knowledge, this is the first time that trihexylamine and N ‐methyldihexylamine have been reported in such systems. We hypothesize that these are derived from the formic acid manufacturing process and recommend that users monitor purchased formic acid for the presence of impurities.Keywords
This publication has 14 references indexed in Scilit:
- Non-targeted screening approaches for contaminants and adulterants in food using liquid chromatography hyphenated to high resolution mass spectrometryJournal of Chromatography A, 2016
- Carbon Dioxide Hydrogenation to Formic Acid by Using a Heterogeneous Gold CatalystAngewandte Chemie International Edition, 2011
- A Process for the Synthesis of Formic Acid by CO2 Hydrogenation: Thermodynamic Aspects and the Role of COAngewandte Chemie International Edition, 2011
- Effect of ionization suppression by trace impurities in mobile phase water on the accuracy of quantification by high‐performance liquid chromatography/mass spectrometryRapid Communications in Mass Spectrometry, 2010
- Interferences and contaminants encountered in modern mass spectrometryAnalytica Chimica Acta, 2008
- Volatile polydimethylcyclosiloxanes in the ambient laboratory air identified as source of extreme background signals in nanoelectrospray mass spectrometryJournal of Mass Spectrometry, 2003
- Plasticizer contamination from vacuum system o-rings in a quadrupole ion trap mass spectrometerJournal of the American Society for Mass Spectrometry, 2002
- Automated data massaging, interpretation, and e-mailing modules for high throughput open access mass spectrometryJournal of the American Society for Mass Spectrometry, 1999
- Electrospray Ionization for Mass Spectrometry of Large BiomoleculesScience, 1989
- Trace impurities in solvents commonly used for gas chromatographic analysis of environment samplesJournal of Chromatography A, 1981