Reproducibility of the acetylene rebreathe technique for determining cardiac output
Authors:
- 1 June 1998
- journal article
- special communications
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 30 (6) , 952-957
Abstract
Reproducibility of the acetylene rebreathe technique for determining cardiac output. Med. Sci. Sports Exerc., Vol. 30, No. 6. pp. 952-957, 1998. Purpose: The acetylene rebreathe technique is a well established method for the determination of cardiac output (Q˙) at rest and during exercise. We sought to demonstrate that the acetylene rebreathe technique allows for highly reproducible determinations of Q˙. Methods: Nine elite male endurance cyclists (V˙O2max = 68.9 ± 0.6 mL·kg−1·min−1) performed a modified acetylene rebreathe maneuver during incremental exercise on four repeat test days. A key modification to the method originally described by Grollman was the maintenance of a positive filling pressure during the inhalation portion of the procedure. Results: There were no significant differences in determinations of Q˙ at the same submaximal heart rates on four separate test days. The coefficient of variation for repeat determinations of maximal Q˙ during the same work rate, expressed as the standard deviation of the difference between duplicate measurements, is 4.8%. The coefficient of variation for determinations of maximal Q˙ at the same heart rate on different days, expressed as the standard deviation of the difference between four test days, is 2.6%. Conclusion: These findings illustrate that the acetylene rebreathe technique can be used with confidence to assess Q˙ across repeated experimental days.Keywords
This publication has 31 references indexed in Scilit:
- Endurance athletes?? stroke volume does not plateauMedicine & Science in Sports & Exercise, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Effect of induced erythrocythemia on aerobic work capacityJournal of Applied Physiology, 1980
- Comparison of cardiac output determined by CO2 rebreathing and dye-dilution methodsJournal of Applied Physiology, 1968
- Effect of training on circulatory response to exercise.Journal of Applied Physiology, 1968
- Errors of the Dye Dilution Method Compared to the Direct Fick Method in Determination of Cariac Output in ManScandinavian Journal of Clinical and Laboratory Investigation, 1966
- Measurement of pulmonary blood flow during exercise using nitrous oxideJournal of Applied Physiology, 1962
- The Cardiac Output in Rest and Work Determined Simultaneously by the Acetylene and the Dye Injection Methods.Acta Physiologica Scandinavica, 1953
- MEASUREMENT OF CARDIAC OUTPUT IN MAN USING THE TECHNIQUE OF CATHETERIZATION OF THE RIGHT AURICLE OR VENTRICLEJournal of Clinical Investigation, 1945
- THE DETERMINATION OF THE CARDIAC OUTPUT OF MAN BY THE USE OF ACETYLENEAmerican Journal of Physiology-Legacy Content, 1929