CardioTrace: An Open-Source Browser-Based Platform for Real-Time RR Interval Acquisition and Event Annotation in Public Health and Environmental Heart Rate Variability Research
Preprint
- 2 November 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Wearable sensors provide RR-interval (time between successive heartbeats) data for heart rate variability (HRV) research, but research-grade acquisition is limited by proprietary applications, restricted raw-data access, limited event annotation, and weak links to reproducible workflows. We developed CardioTrace, an open-source, browser-based application that acquires, visualizes, annotates, and exports RR intervals from the Polar H10 chest strap via Bluetooth Low Energy. It needs no installation, keeps data on the researcher’s device, stores raw and artifact-filtered streams in parallel, auto-saves sessions when the link is lost, runs timed protocols with automatic event markers, and exports CSV, TXT, ZIP, JSON, plot images, or reports. We verified it with two simultaneously worn straps (one paired to EliteHRV), by comparing computed indices with NeuroKit2 on real and synthetic data, and with 39 simulated-sensor tests. The RR series were near-identical (R2 = 0.9999; root mean squared error = 0.62 ms), time-domain and Poincaré indices agreed with NeuroKit2 within 0.1%, wavelet-based low-to-high-frequency power ratios (LF/HF) exceeded the true value by 1–8% on synthetic signals, and all tests passed. CardioTrace standardizes the acquisition layer preceding HRV analysis in public health, occupational, and field studies; limitations include event timing bounded by Bluetooth latency and descriptive spectral indices.Keywords
All Related Versions
This publication has 18 references indexed in Scilit:
- The Immune‐Autonomic Interface in Aging: Baseline Immune Profile Shapes Cardiac Autonomic Response to ExerciseAging Cell, 2026
- Enhancing cardiovascular monitoring: a non-linear model for characterizing RR interval fluctuations in exercise and recoveryScientific Reports, 2025
- Publication guidelines for human heart rate and heart rate variability studies in psychophysiology—Part 1: Physiological underpinnings and foundations of measurementPsychophysiology, 2024
- RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exerciseEuropean Journal of Applied Physiology, 2019
- Kubios HRV – Heart rate variability analysis softwareComputer Methods and Programs in Biomedicine, 2014
- Age-predicted maximal heart rate revisitedJACC, 2001
- Do existing measures of Poincare plot geometry reflect nonlinear features of heart rate variability?IEEE Transactions on Biomedical Engineering, 2001
- Heart Rate VariabilityCirculation, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Monotone Piecewise Cubic InterpolationSIAM Journal on Numerical Analysis, 1980