Usefulness of permutation entropy as an anesthetic depth indicator in children
- 4 February 2015
- journal article
- Published by Springer Nature in Journal of Pharmacokinetics and Pharmacodynamics
- Vol. 42 (2) , 123-134
Abstract
Permutation entropy (PE) as a complexity measure has been introduced to monitor anesthetic depth for adult. However, PE has not yet been evaluated for its clinical applicability as an indicator of anesthetic depth in children. Therefore, in order to investigate the validity of PE, we compared PE with BIS using pharmacodynamic (PD) modeling in children. Electroencephalogram (EEG) was obtained from BIS monitor during sevoflurane deepening and lightening protocol. End-tidal sevoflurane concentration (Etsevo) and BIS were measured simultaneously. PE was calculated from the processed EEG with the scale ranging from 0 to 100. NONMEM software was used to investigate the PD relationship between Etsevo with BIS and PE. Adjusted PE (APE) values were decreased as anesthesia deepened. APE and BIS showed significant linear correlation (P < 0.001), indicating that PE also reflects anesthesia depth. PD parameters for APE and BIS were estimated with a sigmoid Emax model which describes the relationship between Etsevo and APE/BIS (E o : 78, E max : 17.6, C e50 : 2.5 vol%; γ: 13.1, k eo : 0.47 min−1 for APE; E o : 89.4; E max : 15.7; C e50 : 2.2 vol%; γ: 6.6, keo: 0.52 min−1 for BIS). PE seems to be a useful indicator of anesthetic depth, which is comparable to BIS in children.Keywords
This publication has 26 references indexed in Scilit:
- Spectral Entropy and Bispectral Index as Measures of the Electroencephalographic Effects of SevofluraneAnesthesiology, 2004
- Narcotrend Monitoring Allows Faster Emergence and a Reduction of Drug Consumption in Propofol–Remifentanil AnesthesiaAnesthesiology, 2003
- Electroencephalogram Approximate Entropy Correctly Classifies the Occurrence of Burst Suppression Pattern as Increasing Anesthetic Drug EffectAnesthesiology, 2000
- Clinical impact of hypnotic-titration guidelines based on EEG Bispectral Index (BIS) monitoring during routine anesthetic careJournal of Clinical Anesthesia, 2000
- EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recoveryActa Anaesthesiologica Scandinavica, 1999
- Assessment of anaesthesia depthActa Anaesthesiologica Scandinavica, 1996
- Discrimination of sleep stages: a comparison between spectral and nonlinear EEG measuresElectroencephalography and Clinical Neurophysiology, 1996
- Chaos and physiology: deterministic chaos in excitable cell assembliesPhysiological Reviews, 1994
- Changes in EEG Spectral Edge Frequency Correlate with the Hemodynamic Response to Laryngoscopy and IntubationAnesthesiology, 1987
- Estimation of the Kolmogorov entropy from a chaotic signalPhysical Review A, 1983