Performance enhancement of DFBL based near‐infrared CH4 telemetry system using a focus tunable lens
Authors:
- 21 November 2020
- journal article
- research article
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 63 (4) , 1147-1151
Abstract
A methane telemetry system for 1653 nm DFB laser based on TDLAS‐WMS technology is developed in this article. The focus tunable lens is used as the collimating system of the telemetry device to solve the problem that the telemetry device cannot be dynamically adjusted under different detection environments. Experimental results show that the root mean square error was 7.6205 and the theoretical limit of detection (LoD) was 1.473 parts per million (ppm) while the optimal integration time reaches 30 s. The near‐infrared CH4 telemetry system is suitable for different detection environments of natural gas leakage and has good detection performance and stable and reliable operation.Keywords
This publication has 13 references indexed in Scilit:
- Trace gas sensing based on multi-quartz-enhanced photothermal spectroscopyPhotoacoustics, 2020
- Sensitive methane detection based on quartz-enhanced photoacoustic spectroscopy with a high-power diode laser and wavelet filteringOptics and Lasers in Engineering, 2020
- Ppb-level formaldehyde detection system based on a 3.6 µm interband cascade laser and mode-locked cavity enhanced absorption spectroscopy with self-calibration of the locking frequencyInfrared Physics & Technology, 2020
- Highly sensitive acetylene detection based on multi-pass retro-reflection-cavity-enhanced photoacoustic spectroscopy and a fiber amplified diode laserOptics Express, 2019
- Active standoff detection of CH4 and N2O leaks using hard-target backscattered light using an open-path quantum cascade laser sensorApplied Physics B, 2016
- Simultaneous atmospheric nitrous oxide, methane and water vapor detection with a single continuous wave quantum cascade laserOptics Express, 2015
- Single-QCL-based absorption sensor for simultaneous trace-gas detection of CH4 and N2OApplied Physics B, 2014
- Tunable multi-mode diode laser absorption spectroscopy for methane detectionSensors and Actuators A: Physical, 2013
- Simulation-based comparison of noise effects in wavelength modulation spectroscopy and direct absorption TDLASApplied Physics B, 2010
- High-sensitivity, large dynamic range, auto-calibration methane optical sensor using a short confocal Fabry–Perot cavitySensors and Actuators B: Chemical, 2007