Accuracy of Proximal Caries Depth Measurements: Comparison between Limited Cone Beam Computed Tomography, Storage Phosphor and Film Radiography
Authors:
- B. Güniz AkdenizBAB. Güniz Akdeniz
- Hans-Göran GröndahlHGHans-Göran Gröndahl
- Bengt MagnussonBMBengt Magnusson
- 1 May 2006
- journal article
- research article
- Published by S. Karger AG in Caries Research
- Vol. 40 (3) , 202-207
Abstract
The aim of this study was to compare the accuracy of limited cone beam computed tomography (LCBCT), an image plate system and F-speed film in assessing the depth of proximal carious lesions. Radiographs of a dry mandible with sound and carious teeth were obtained with all three methods. In 41 molar and premolar proximal surfaces, 2 observers independently measured lesion depth on the images from the three modalities. The correlation of measurements was assessed with Pearson’s correlation analysis. Results from imaging modalities and histological sectioning (gold standard) were compared using Bland-Altman plots. Overall comparison of the depth measurements from the imaging modalities and the gold standard was done using repeated-measures ANOVA. Pairwise comparisons of systems were done by the Bonferroni t test. The correlation between the measurements of the two observers was 0.977 for film, 0.997 for image plate system and 0.998 for LCBCT. Bland-Altman plots revealed that LCBCT agreed very closely with the gold standard while the agreement between the latter and the image plate – or film – images was moderate. The mean difference and 95% limits of agreement between LCBCT and the gold standard were smaller than those between either image plate or F-speed film and the gold standard. The LCBCT method appears as a promising tool for detection and monitoring of proximal carious lesions.Keywords
This publication has 14 references indexed in Scilit:
- Relationship between Histological and Radiographic Caries Lesion Depth Measured in Images from Four Digital Radiography SystemsCaries Research, 2003
- Accuracy of computer‐automated caries detection in digital radiographs compared with human observersEuropean Journal of Oral Sciences, 2002
- Influence of the number of basis images and projection array on caries detection using tuned aperture computed tomography (TACT)Dentomaxillofacial Radiology, 2002
- Effect of angular disparity of basis images and projection geometry on caries detection using tuned-aperture computed tomographyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2001
- Development of a compact computed tomographic apparatus for dental useDentomaxillofacial Radiology, 1999
- Digital radiography and caries diagnosis.Dentomaxillofacial Radiology, 1998
- Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study.Dentomaxillofacial Radiology, 1995
- In vitro Study into the Influence of X-Ray Beam Angulation on the Detection if Artificial Caries Defects on Bitewing RadiographsCaries Research, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Clinical and radiographic assessment of approximal carious lesionsActa Odontologica Scandinavica, 1986