A Time‐Related Study of the Hemodynamic Benefit of Atrioventricular Synchronous Pacing Evaluated by Doppler Echocardiography
Authors:
- 1 November 1985
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 8 (6) , 838-848
Abstract
We have used Doppler echocardiography to estimate the stroke volume (SV) in a study of 13 patients equipped with DDD pacemakers. SV was measured both during DDD and WI pacing after observation times of 1,3, 6, and 12 months of DDD pacing. SV was also measured at seven atrioventricular (AV) intervals (75–250 ms) in the search for optimal AV intervals. Mitral flow velocity was investigated to see if DDD pacing resulted in synchronous atrial contraction, and if mitral insufficiency existed at any of the pacing modes. Compared with the VVI mode, DDD pacing resulted in a mean increase in SV of 21 ± 2% for the four observation periods. Two patients with severe left ventricular failure had no significanl increase in SV during DDD vs VVI pacing. In each patient, an optimal AV inlerval ranging between 100–250 ms for the SV was found. Velocity profiles of mitral flow showed synchronous atrial contraction during DDD pacing, but not during VVI pacing. Mitral insufficiency was not seen in any pacing mode. DDD pacing resulted in a reduction in SV during the first 6 months, and was constant thereafter. Doppler echocardiography can be used repeatedly to evaluate the hemodynamic response of DDD pacing vs VVI pacing, and to find which AV interval gives the highest SV in the individual patient. Our study further shows that the hemodynamic benefit of DDD pacing is present after short‐term as well as after long‐term DDD pacing.Keywords
This publication has 18 references indexed in Scilit:
- Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.Circulation, 1984
- Comparative Functional Effects of Chronic Ventricular Demand and Atrial Synchronous Ventricular Inhibited PacingPacing and Clinical Electrophysiology, 1984
- Usefulness of Doppler Echocardiography in Cardiac Pacing: Assessment of Mitral Regurgitation, Peak Aortic Flow Velocity and Atrial CapturePacing and Clinical Electrophysiology, 1983
- Comparison of Resting Hemodynamic Indices and Exercise Performance During Atrial Synchronized and Asynchronous Ventricular PacingPacing and Clinical Electrophysiology, 1983
- Reevaluation of the role of atrial systole to cardiac hemodynamics: Evidence for pulmonary venous regurgitation during abnormal atrioventricular sequencingAmerican Heart Journal, 1983
- The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.Circulation, 1983
- Hemodynamic effects of acute atrioventricular sequential pacing in patients with left ventricular dysfunctionThe American Journal of Cardiology, 1982
- A new technique for measurement of cardiac output by thermodilution in manThe American Journal of Cardiology, 1971
- The influence of atrial contraction and mitral valve mechanics on ventricular fillingAmerican Heart Journal, 1969
- Re-evaluation of the atrial contribution to ventricular functionThe American Journal of Cardiology, 1968