Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters
Open Access
- 5 September 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 118-132
Abstract
Purpose: To investigate and mitigate the influence of physiological and acquisition‐related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL).Methods: A Flow‐sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch‐equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and blood relaxation time () affect quantification of myoASL‐MBF. In vivo myoASL‐images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject‐specific values and, for spGRE imaging, subtracting an additional saturation‐prepared baseline from the original baseline signal.Results: Simulated and phantom experiments showed a strong dependence on AMS and FA (>0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation‐baseline correction in spGRE. Only a very mild HR dependence (>0.59) was observed which was reduced when calculating MBF with individual . For corrected spGRE, in vivo mean global spGRE‐MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra‐subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter‐subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP.Conclusion: Our results show that physiological and acquisition‐related factors can lead to spurious changes in myoASL‐MBF if not accounted for. Using individual and a saturation‐baseline can reduce these variations in spGRE and improve reproducibility of FAIR‐myoASL against acquisition parameters.Keywords
This publication has 67 references indexed in Scilit:
- Cardiovascular magnetic resonance artefactsJournal of Cardiovascular Magnetic Resonance, 2013
- Myocardial Perfusion Using Arterial Spin Labeling CMRJACC: Cardiovascular Imaging, 2011
- Estimation of perfusion and arterial transit time in myocardium using free‐breathing myocardial arterial spin labeling with navigator‐echoMagnetic Resonance in Medicine, 2010
- Arterial transit time effects in pulsed arterial spin labeling CBF mapping: Insight from a PET and MR study in normal human subjectsMagnetic Resonance in Medicine, 2009
- Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): Feasibility and noise analysisMagnetic Resonance in Medicine, 2009
- Heart rate in the pathophysiology of coronary blood flow and myocardial ischaemia: benefit from selective bradycardic agentsBritish Journal of Pharmacology, 2008
- Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the artJournal of Cardiovascular Magnetic Resonance, 2008
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heartMagnetic Resonance in Medicine, 2004
- Quantification of regional myocardial blood flow in vivo with H215O.Circulation, 1984