Pre-calculated duty cycle control implemented in FPGA for power factor correction
Open Access
- 1 November 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2955-2960
Abstract
A power factor correction (PFC) technique based on pre-calculated duty cycle values is presented in this paper. In this method the duty ratios for half a line period are calculated in advance and stored in a memory. By synchronizing the memory with the line, near unity power factors can be achieved in a specific operating point. The main advantage of this technique is that neither current measurement nor current loop are needed. To obtain stable output voltages a voltage loop is included. A boost converter prototype controlled by an FPGA evaluation board has been implemented in order to verify the functionality of the proposed method. Both the simulation and experimental results show that near unity power factor can be achieved with this PFC strategy.Keywords
This publication has 8 references indexed in Scilit:
- Current Sensorless Power Factor Correction based on Digital Current Rebuilding2009
- Single-Loop Current Sensorless Control for Single-Phase Boost-Type SMRIEEE Transactions on Power Electronics, 2009
- A New Duty Cycle Control Strategy for Power Factor Correction and FPGA ImplementationIEEE Transactions on Power Electronics, 2006
- Dead-zone digital controllers for improved dynamic response of low harmonic rectifiersIEEE Transactions on Power Electronics, 2006
- A Digital Power Factor Correction (PFC) Control Strategy Optimized for DSPIEEE Transactions on Power Electronics, 2004
- Self-tuning digitally controlled low-harmonic rectifier having fast dynamic responseIEEE Transactions on Power Electronics, 2003
- Concurrent and simple digital controller of an AC/DC converter with power factor correction based on an FPGAIEEE Transactions on Power Electronics, 2003
- Stored-duty-ratio control for power factor correction1999