Cerebral foreign body reaction due to hydrophilic polymer embolization following aneurysm treatment by pipeline flow diversion device
- 28 March 2019
- journal article
- case report
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 25 (4) , 447-453
Abstract
The use of flow diverting stents for wide based, intracranial aneurysms has become an invaluable treatment option. While intracranial hemorrhage and ischemic stroke from dislodged atherosclerotic emboli are common adverse events, the potential for delayed granulomatous inflammation from possible hydrophilic polymer emboli is rarely recognized. We present a unique case in which visible chipping of the pusher wire for stent placement was observed, followed by clinical and radiographic evidence suggestive of a delayed foreign body reaction to intracranial hydrophilic polymer emboli. A 55-year-old woman underwent placement of a Pipeline embolization device for a left-sided, broad-based aneurysm at the base of the internal carotid artery and posterior communicating artery. Two months later she developed right-sided focal neurological deficits. Imaging showed ipsilateral focal edema and enhancing lesions with contrast. Although not confirmed with biopsy and histopathology, clinical and radiographic evidence suggests that this patient probably experienced a delayed foreign body reaction to hydrophilic polymer emboli from compromised procedural equipment during flow diverting stent placement. Although previously described, this is the first instance to our knowledge in whichvisible chipping of the pusher wire was observed on a Pipeline embolization device.Keywords
This publication has 17 references indexed in Scilit:
- Cutaneous microemboli from hydrophilic polymer after endovascular proceduresJournal of the American Academy of Dermatology, 2015
- Foreign Body Emboli following Cerebrovascular Interventions: Clinical, Radiographic, and Histopathologic FeaturesAmerican Journal of Neuroradiology, 2015
- Distal Embolization of Hydrophilic-Coating Material From Coronary Guidewires After Percutaneous Coronary InterventionsCirculation: Cardiovascular Interventions, 2015
- Hydrophilic polymer embolism and associated vasculopathy of the lung: prevalence in a retrospective autopsy studyHuman Pathology, 2015
- Enhancing Brain Lesions after Endovascular Treatment of AneurysmsAmerican Journal of Neuroradiology, 2014
- Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization DeviceJournal of Neurosurgery, 2014
- Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical TrialRadiology, 2013
- Polymer Embolization From Minimally Invasive InterventionsAmerican Journal of Kidney Diseases, 2013
- Intravascular polymer material after coil embolization of a giant cerebral aneurysmHuman Pathology, 2009
- Complications of Endovascular Polymers Associated With Vascular Introducer Sheaths and Metallic Coils in 3 Patients, With Literature ReviewAmerican Journal of Surgical Pathology, 2008