Impact of intra-aortic balloon counterpulsation with different balloon volumes on cardiac performance in humans
- 30 September 2002
- journal article
- clinical trial
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 199-204
Abstract
Intra‐aortic balloon (IAB) counterpulsation can augment the cardiac output. However, the effect of different IAB volumes on cardiac performance has not been adequately evaluated in humans. Eighty‐two patients (52 males [63%]; mean age, 65 ± 12 years; mean body surface area [BSA], 1.8 ± 0.2 m2) had IAB counterpulsation for cardiogenic shock, refractory angina, and preoperatively for high‐risk cardiac surgery. Cardiac hemodynamics were prospectively studied during IAB with inflation volumes of 32 vs. 40 cc. Hemodynamic data collected included aortic pressure, pulmonary artery pressure, systemic and mixed venous oxygen saturations, and cardiac output (by Fick). Transthoracic echocardiography (TTE) was used to obtain both velocity time integrals (VTIs) and the area of the left ventricular outflow tract (LVOT). Left ventricular stroke volume was then calculated as LVOT area × VTI. Cardiac output (CO) determined by the Fick method and VTI did not differ significantly (P = NS) between the two inflation volumes (y = 0.002 + 0.97×). In a subgroup of 33 patients with BSA ≤ 1.8 m2, the CO (by VTI) was slightly lower with IAB inflation volume of 32 vs. 40 cc (P = 0.05). Overall, smaller IAB inflation volumes do not affect the hemodynamic improvement seen during IAB counterpulsation. However, in patients with smaller BSA, larger inflation volumes may further augment CO. Cathet Cardiovasc Intervent 2002;57:199–204.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of outcomes after 8 vs. 9.5 French size intra-aortic balloon counterpulsation catheters based on 9,332 patients in the prospective Benchmark® registryCatheterization and Cardiovascular Interventions, 2002
- Reduction in ischemic vascular complications with a hydrophilic-coated intra-aortic balloon catheterCatheterization and Cardiovascular Interventions, 1999
- Prospective evaluation of complications associated with percutaneous intraaortic balloon counterpulsationThe American Journal of Cardiology, 1995
- Pilot prospective evaluation of counterpulsation with different intra‐aortic balloon volumes on cardiac performance in humansCatheterization and Cardiovascular Diagnosis, 1995
- 709-4 Intraaortic Balloon Pump Counterpulsation in Octogenarians: Outcome and ComplicationsJACC, 1995
- The hostile environment of the aging human aorta and the smaller patient- their implications for the intra-aortic balloonPerfusion, 1994
- Complications associated with percutaneous placement and use of intraaortic balloon counterpulsationThe American Journal of Cardiology, 1993
- Identification of patients at high risk for complications of intraaortic balloon counterpulsation: A multivariate risk factor analysisThe American Journal of Cardiology, 1984
- Comparison of noninvasive pulsed Doppler and Fick measurements of stroke volume in cardiac patientsAmerican Heart Journal, 1984
- Augmentation of regional coronary blood flow by intra-aortic balloon counterpulsation in patients with unstable angina.Circulation, 1983