Inter-laboratory comparison of gene expression biodosimetry for protracted radiation exposures as part of the RENEB and EURADOS WG10 2019 exercise
Authors:
Open Access
- 7 May 2021
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-15
Abstract
Large-scale radiation emergency scenarios involving protracted low dose rate radiation exposure (e.g. a hidden radioactive source in a train) necessitate the development of high throughput methods for providing rapid individual dose estimates. During the RENEB (Running the European Network of Biodosimetry) 2019 exercise, four EDTA-blood samples were exposed to an Iridium-192 source (1.36 TBq, Tech-Ops 880 Sentinal) at varying distances and geometries. This resulted in protracted doses ranging between 0.2 and 2.4 Gy using dose rates of 1.5–40 mGy/min and exposure times of 1 or 2.5 h. Blood samples were exposed in thermo bottles that maintained temperatures between 39 and 27.7 °C. After exposure, EDTA-blood samples were transferred into PAXGene tubes to preserve RNA. RNA was isolated in one laboratory and aliquots of four blinded RNA were sent to another five teams for dose estimation based on gene expression changes. Using an X-ray machine, samples for two calibration curves (first: constant dose rate of 8.3 mGy/min and 0.5–8 h varying exposure times; second: varying dose rates of 0.5–8.3 mGy/min and 4 h exposure time) were generated for distribution. Assays were run in each laboratory according to locally established protocols using either a microarray platform (one team) or quantitative real-time PCR (qRT-PCR, five teams). The qRT-PCR measurements were highly reproducible with coefficient of variation below 15% in ≥ 75% of measurements resulting in reported dose estimates ranging between 0 and 0.5 Gy in all samples and in all laboratories. Up to twofold reductions in RNA copy numbers per degree Celsius relative to 37 °C were observed. However, when irradiating independent samples equivalent to the blinded samples but increasing the combined exposure and incubation time to 4 h at 37 °C, expected gene expression changes corresponding to the absorbed doses were observed. Clearly, time and an optimal temperature of 37 °C must be allowed for the biological response to manifest as gene expression changes prior to running the gene expression assay. In conclusion, dose reconstructions based on gene expression measurements are highly reproducible across different techniques, protocols and laboratories. Even a radiation dose of 0.25 Gy protracted over 4 h (1 mGy/min) can be identified. These results demonstrate the importance of the incubation conditions and time span between radiation exposure and measurements of gene expression changes when using this method in a field exercise or real emergency situation.Keywords
Funding Information
- Sanitätsakademie der Bundeswehr
This publication has 56 references indexed in Scilit:
- Radiation-Induced Micro-RNA Expression Changes in Peripheral Blood Cells of Radiotherapy PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Whole mouse blood microRNA as biomarkers for exposure to 𝛄-rays and56Fe ionsInternational Journal of Radiation Biology, 2011
- Prediction of In Vivo Radiation Dose Status in Radiotherapy Patients using Ex Vivo and In Vivo Gene Expression SignaturesRadiation Research, 2011
- Gene expression following ionising radiation: Identification of biomarkers for dose estimation and prediction of individual responseInternational Journal of Radiation Biology, 2010
- BIODOSIMETRY ON SMALL BLOOD VOLUME USING GENE EXPRESSION ASSAYHealth Physics, 2010
- The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR ExperimentsClinical Chemistry, 2009
- Development of Gene Expression Signatures for Practical Radiation BiodosimetryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Biomarkers for human radiation exposureJournal of Biomedical Science, 2008
- Gene Expression Signatures That Predict Radiation Exposure in Mice and HumansPLOS Medicine, 2007
- Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water; Technical Reports Series No. 398,Health Physics, 2001