Prediction of Bond-Slip Behavior of Circular/Squared Concrete-Filled Steel Tubes
Open Access
Abstract
Numerous existing formulas predicted the ultimate interfacial bond strength in concrete-filled steel tubes (CFST) between steel tubes and concrete core without investigating the whole response under push-out load. In this research, four models are proposed to predict the interfacial behavior in CFST including the post-peak branch under the push-out loading test based on 157 circular specimens and 105 squared specimens from the literature. Two models (one for circular and one for squared CFST) are developed and calibrated using artificial neural network (ANN) and two models (one for circular and one for squared CFST) are developed based on multivariable regression analysis, analysis of variance (ANOVA). The shape of the specimen (circular or squared), diameter of the tube, thickness of the tube, concrete compressive strength, age at the time of testing, and length of the specimen are the main factors considered. These models are then compared to other existing formulas to verify their capability to better predict the ultimate interfacial bond strength. It is found that the ANN model gives better results for most of the considered data. It is also found that ANN models can predict the overall bond-slip response for the considered dataset. In order to simulate the response of any CFST column using finite element (FE) method, it is vital to have sufficient input data on the overall bond-slip behavior between the interior face of the steel tube and the exterior surface of the concrete core including the post-peak branch. Accordingly, the suggested ANN model is used to generate the required input data related to the cohesive behavior and damage along the interface in ABAQUS model to simulate the response of two circular and two squared CFST columns under concentric compressive load. The results are in good agreement with experimental outcomes. The cohesive criterion and damage interface that are used based on ANN models in FE are found to be sufficient and can be adopted to model CFST columns.Keywords
This publication has 38 references indexed in Scilit:
- Load-reversed push-out tests on rectangular CFST columnsJournal of Constructional Steel Research, 2013
- Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columnsJournal of Constructional Steel Research, 2011
- Incremental collapse threshold for pushout resistance of circular concrete filled steel tubular columnsJournal of Constructional Steel Research, 2010
- Push-off tests on pin-connected shear studs with composite steel–concrete beamsConstruction and Building Materials, 2009
- Use of artificial neural network simulation metamodelling to assess groundwater contamination in a road projectMathematical and Computer Modelling, 2007
- Performance of concrete-filled thin-walled steel tubes under pure torsionThin-Walled Structures, 2007
- Axial Load Behavior of Stiffened Concrete-Filled Steel ColumnsJournal of Structural Engineering, 2002
- Influence of Concrete Compaction on the Behavior of Concrete Filled Steel Tubes with Rectangular SectionsAdvances in Structural Engineering, 2001
- Composite Action in Concrete Filled TubesJournal of Structural Engineering, 1999
- Uniaxial Compressional Stress‐Strain Relation of ConcreteJournal of Structural Engineering, 1988