Argatroban for anticoagulation of a blood salvage system - an ex-vivo study
Open Access
- 1 December 2015
- journal article
- research article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 16 (1) , 1-7
Abstract
Blood salvage systems help to minimize intraoperative transfusion of allogenic blood. So far no data is available on the use of argatroban for anticoagulation of such systems. We conducted an ex-vivo trial to evaluate the effectiveness of three different argatroban doses as compared to heparin and to assess potential residual anticoagulant in the red cell concentrates. With ethical approval and individual informed consent, blood of 23 patients with contraindications for use of blood salvage systems during surgery was processed by the Continuous-Auto-Transfusion-System (C.A.T.S. ® Cell Saver System, Fresenius Kabi, Bad Homburg, Germany) using 5,50 or 250 mg of argatroban or 25.000 U of heparin in 1000 ml saline for anticoagulation of the system. Emergency and high-quality washing modes were applied in random order. Patency of the system and residual amount of anticoagulants in the re-transfusion bag were measured. The collected blood was not re-infused, but only used for analysis of hematocrit, heparin and argatroban concentrations. Patency of the system was provided by all anticoagulants except for 3/8 cases with 5 mg of argatroban. Residual anticoagulant was found in 2/10 (20 %) heparin samples in two different patients (1 emergency and 1 high-quality washing) and in all argatroban samples. High quality washing eliminated 89–95 % and emergency washing 60–90 % of the initial argatroban concentration. Residual argatroban concentrations ranged from 55 ng ml−1 to 6810 ng ml−1, with initial argatroban concentrations of 5 and 250 mg, respectively. The C.A.T.S. does not reliably remove heparin and should therefore not be used in HIT patients. Anticoagulation with 50 and 250 mg argatroban, maintains the systems patency and is significantly removed during washing. In this ex-vivo study a concentration of 50 μg ml−1 argatroban provided the best ratio of system patency and residual argatroban concentration. Additional dose-finding studies with different blood salvage systems are needed to evaluate the optimal argatroban concentration.Keywords
Funding Information
- Mitsubishi Tanabe Pharma
This publication has 24 references indexed in Scilit:
- Patient blood management in EuropeBritish Journal of Anaesthesia, 2012
- Development of a fast and simple liquid chromatography–tandem mass spectrometry method for the quantitation of argatroban in patient plasma samplesJournal of Chromatography B, 2012
- Treatment and Prevention of Heparin-Induced ThrombocytopeniaChest, 2012
- Perioperative Management of Antithrombotic TherapyChest, 2012
- Cell salvage for minimising perioperative allogeneic blood transfusion2010
- Successful Use of Bivalirudin as Anticoagulant for ECMO in a Patient With Acute HITThe Annals of Thoracic Surgery, 2007
- Argatroban in Extracorporeal Membrane OxygenationArtificial Organs, 2007
- Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in Europe*Transfusion, 2003
- Clinical Evaluation of Autotransfusion During Liver TransplantationAnesthesia & Analgesia, 1991
- Heparin-Elimination und freies Hämoglobin nach Zellseparation und Waschen autologen Blutes mit dem Cell-Saver 4AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 1988