Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver model
- 25 March 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 92A (3) , 1154-1161
Abstract
Meniscal substitutes should ideally distribute loads across adjacent articular cartilage much in the way of the native tissue, thereby protecting the cartilage from degeneration. The objective of this study was to quantify the loads transferred to the tibial plateau after implantation of a porous polyurethane scaffold. Our hypothesis was that scaffold implantation would improve the contact mechanics of a partial meniscectomy knee. Six sheep cadaver knees were mounted in a load‐controlled knee‐joint simulator. A pressure‐sensor sheet, secured to the tibial plateau, dynamically recorded pressure data over 10 gait cycles for the following conditions: (i) intact, (ii) partial meniscectomy, (iii) implanted scaffold, and (iv) total meniscectomy. Implantation of the scaffold increased the contact area and decreased the contact pressures compared to the meniscal defect knee. No significant difference was found between the average and peak contact pressures of the intact knees and scaffold‐implanted knees; however, contact area was significantly lower for the scaffold‐implanted knees compared to intact knees. Our hypothesis was accepted; replacement with a polyurethane scaffold improved knee‐contact mechanics relative to a partially meniscectomized knee. On the basis of these findings, the scaffold will be evaluated for its chondroprotective capacity in an in vivo ovine model. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010Keywords
This publication has 40 references indexed in Scilit:
- A new technique to measure the dynamic contact pressures on the Tibial PlateauJournal of Biomechanics, 2008
- Meniscal Allograft TransplantationClinical Orthopaedics and Related Research, 2007
- The consequences of meniscectomyThe Journal of Bone and Joint Surgery. British volume, 2006
- Experimental Measurement of Tibiofemoral Contact Area in a Meniscectomized Ovine Model Using a Resistive Pressure Measuring SensorAnnals of Biomedical Engineering, 2006
- Tibiofemoral Contact Mechanics after Serial Medial Meniscectomies in the Human Cadaveric KneeThe American Journal of Sports Medicine, 2006
- Long-term Outcome for Large Meniscal Defects Treated with Small Intestinal Submucosa in a Dog ModelThe American Journal of Sports Medicine, 2006
- The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: A study in human cadaveric kneesJournal of Orthopaedic Research, 2003
- Meniscal tissue regeneration in porous 50/50 copoly(l-lactide/ε-caprolactone) implantsBiomaterials, 1997
- Meniscal replacement using a porous polymer prosthesis: a preliminary study in the dogBiomaterials, 1996
- Interspecies variation of compressive biomechanical properties of the meniscusJournal of Biomedical Materials Research, 1995