Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
Open Access
Abstract
In this paper, an indirect method of measuring an analyte concentration in a test solution using the resonant frequency change of a Helmholtz resonator is proposed, using a novel architecture of Helmholtz resonator filled with two kinds of fluids (fixed fluid and test solution). Since the analyte concentration yields changes of density and sound speed of the test solution, the resonant frequency of the proposed Helmholtz resonator is affected by the analyte concentration of the test solution. From this effect, the analyte concentration of the test solution can be measured by the spectrum of acoustic resonance of the Helmholtz resonator. The experiment was done using a 3D-printed Helmholtz resonator system with an acoustic power source and detectors, which is consistent with analytical results and showed that the analyte concentration can be measured with higher sensitivity compared to conventional cantilever-type sensors. As an example application, the possibility of measuring glucose concentration of human blood was demonstrated, showing higher sensitivity and relatively low frequency range compared to previous resonance based methods.Keywords
Funding Information
- Korea Agency for Infrastructure Technology Advancement (Research Project for Railway Technology)
- Korea Institute of Energy Technology Evaluation and Planning (20184030202000)
This publication has 25 references indexed in Scilit:
- Molecularly imprinted polymer based micromechanical cantilever sensor system for the selective determination of ciprofloxacinBiosensors and Bioelectronics, 2017
- Biosensing using dynamic-mode cantilever sensors: A reviewBiosensors and Bioelectronics, 2012
- Microcantilever-based platforms as biosensing toolsThe Analyst, 2010
- Development of microcantilever-based biosensor array to detect Angiopoietin-1, a marker of tumor angiogenesisBiosensors and Bioelectronics, 2010
- Micro-electromechanical sensors in the analytical fieldThe Analyst, 2009
- Resonant frequency of an adjustable Helmholtz resonator in a hydraulic systemArchive of Applied Mechanics, 2008
- The effect of piezoresistive microcantilever geometry on cantilever sensitivity during surface stress chemical sensingSensors and Actuators A: Physical, 2008
- Enumeration of DNA Molecules Bound to a Nanomechanical OscillatorNano Letters, 2005
- Novel electrical detection of label-free disease marker proteins using piezoresistive self-sensing micro-cantileversBiosensors and Bioelectronics, 2005
- Suspended microchannel resonators for biomolecular detectionApplied Physics Letters, 2003