Comparative Study of Monte Carlo Simulation and the Deterministic Model to Analyze Thermal Insulation Costs
Open Access
- 1 March 2024
- journal article
- research article
- Published by MDPI AG in AppliedMath
- Vol. 4 (1) , 305-319
Abstract
The main purpose of this paper is to implement a simulation model in @RISKTM and study the impact of incorporating random variables, such as the degree days in a traditional deterministic model, for calculating the optimum thickness of thermal insulation in walls. Currently, green buildings have become important because of the increasing worldwide interest in the reduction of environmental pollution. One method of saving energy is to use thermal insulation. The optimum thickness of these insulators has traditionally been calculated using deterministic models. With the information generated from real data using the degree days required in a certain zone in Palestine during winter, random samples of the degree days required annually in this town were generated for periods of 10, 20, 50, and 70 years. The results showed that the probability of exceeding the net present value of the cost calculated using deterministic analysis ranges from 0% to 100%, without regard to the inflation rate. The results also show that, for design lifetimes greater than 40 years, the risk of overspending is lower if the building lasts longer than the period for which it was designed. Moreover, this risk is transferred to whomever will pay the operating costs of heating the building. The contribution of this research is twofold: (a) a stochastic approach is incorporated into the traditional models that determine the optimum thickness of thermal insulation used in buildings, by introducing the variability of the degree days required in a given region; (b) a measure of the economic risk incurred by building heating is established as a function of the years of use for which the building is designed and the number of years it is actually used.Keywords
This publication has 22 references indexed in Scilit:
- Optimization of external wall insulation thickness in buildings using response surface methodologyInternational Journal of Energy and Environmental Engineering, 2022
- Evaluation of the optimal thermal insulation thickness for an office building in different climates by means of the basic and modified “cost-optimal” methodologyJournal of Building Engineering, 2019
- Optimizing insulation thickness of external walls in cold region of Morocco based on life cycle cost analysisEnergy Procedia, 2017
- Optimizing the position of insulating materials in flat roofs exposed to sunshine to gain minimum heat into buildings under periodic heat transfer conditionsEnvironmental Science and Pollution Research, 2015
- Optimization of thermal insulation to achieve energy savings in low energy house (refurbishment)Energy Conversion and Management, 2014
- Experimental comparison between 3 different traditional wall constructions and dynamic simulations to identify optimal thermal insulation strategiesEnergy and Buildings, 2013
- A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loadsApplied Energy, 2011
- An assessment tool for the energy, economic and environmental evaluation of thermal insulation solutionsEnergy and Buildings, 2009
- Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of TurkeyBuilding and Environment, 2008
- The use of tuff stone cladding in buildings for energy conservationConstruction and Building Materials, 2006