Touch imprint (TI) cytology of needle core biopsies (NCB) in pathology laboratories: A practice survey of participants in the College of American Pathologists (CAP) Non Gynecologic Cytopathology (NGC) Education Program
- 23 November 2018
- journal article
- research article
- Published by Wiley in Diagnostic Cytopathology
- Vol. 47 (3) , 149-155
Abstract
Background: Intra‐procedural assessment of touch imprint (TI) cytology from needle core biopsies (NCB) is used to ensure sample adequacy and to provide immediate diagnosis in various settings. We aimed to survey laboratories for current practices on the use of cytology with NCB.Methods: A voluntary supplemental questionnaire including questions on demographics, personnel involved, sites, accessioning, and reporting was sent with the College of American Pathologists (CAP) 2015 Non gynecologic Cytopathology Education Program to survey practices of cytologic assessment of NCB.Results: Among 844 respondents, 403 (48%) performed cytologic assessment of NCB. Common body sites included lung (94%; 368/392), liver (87%; 340/ 392), and lymph nodes/spleen (77%; 303/392). Most of the time, a pathologist was present on‐site 75% (295/393) for adequacy assessment which was usually verbally reported to the provider performing the procedure. Specimens were prepared by cytotechnologists (50%; 193 of 388) or pathologists (45%; 176 of 388) by touching the core to the slide (50%; 196 of 390) and rolling the core on the slide (45%; 177/390). Among the respondents, 19% said that cytotechnologists independently performed immediate assessment of TI of NCB. Most laboratories (69%; 264/384) evaluated air‐dried slides with a modified Giemsa stain and rendered one TI/NCB combined report (87%, 334/385).Conclusions: This is the first survey performed specifically to determine the practice of adequacy assessment of TI of NCB. Cytotechnologists are generally not performing adequacy assessment of TI without pathologist oversight. A single report is usually issued which includes the adequacy assessment as a part of the final report.Keywords
This publication has 14 references indexed in Scilit:
- Increase of core biopsies in visceral organs–experience at one institutionDiagnostic Cytopathology, 2010
- Fine-needle aspiration (FNA) biopsy: historical aspects.Folia Histochemica et Cytobiologica, 2009
- Usefulness of Core Roll Preparations in Immediate Assessment of Neoplastic Lung LesionsChest, 2004
- US-guided Transthoracic Cutting Biopsy for Peripheral Thoracic Lesions Less than 3 cm in DiameterRadiology, 2000
- Percutaneous CT-Guided Biopsy of the Lung: Comparison Between Aspiration and Automated Cutting Needles Using a Coaxial TechniqueCardioVascular and Interventional Radiology, 2000
- CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis.American Journal of Roentgenology, 1998
- Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients.Radiology, 1996
- Cytopathologic touch preparations (imprints) from core needle biopsies: accuracy compared with that of fine-needle aspirates.American Journal of Roentgenology, 1995
- CT-guided automated needle biopsy of the chest.American Journal of Roentgenology, 1995
- CT-guided biopsy of the chest: usefulness of fine-needle core biopsy combined with frozen-section pathologic diagnosis.Radiology, 1994