Normal limits for oscillometric bronchodilator responses and relationships with clinical factors
Open Access
- 9 September 2021
- journal article
- research article
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 7 (4)
Abstract
Introduction: We aimed to determine normal thresholds for positive bronchodilator responses for oscillometry in an Australian general population sample aged ≥40 years, to guide clinical interpretation. We also examined relationships between bronchodilator responses and respiratory symptoms, asthma diagnosis, smoking and baseline lung function.Methods: Subjects recruited from Sydney, Melbourne and Busselton, Australia, underwent measurements of spirometry, resistance (Rrs6) and reactance (Xrs6) at 6 Hz, before and after inhalation of salbutamol 200 μg. Respiratory symptoms and/or medication use, asthma diagnosis, and smoking were recorded. Threshold bronchodilator responses were defined as the fifth percentile of decrease inRrs6and 95th percentile increase inXrs6in a healthy subgroup.Results: Of 1318 participants, 1145 (570 female) were analysed. The lower threshold for ΔRrs6was −1.38 cmH2O·s·L−1(−30.0% or −1.42 Z-scores) and upper threshold for ΔXrs6was 0.57 cmH2O·s·L−1(1.36 Z-scores). Respiratory symptoms and/or medication use, asthma diagnosis, and smoking all predicted bronchodilator response, as did baseline oscillometry and spirometry. When categorised into clinically relevant groups according to those predictors, ΔXrs6was more sensitive than spirometry in smokers without current asthma or chronic obstructive pulmonary disease (COPD), ∼20% having a positive response. Using absolute or Z-score change provided similar prevalences of responsiveness, except in COPD, in which responsiveness measured by absolute change was twice that for Z-score.Discussion: This study describes normative thresholds for bronchodilator responses in oscillometry parameters, including intra-breath parameters, as determined by absolute, relative and Z-score changes. Positive bronchodilator response by oscillometry correlated with clinical factors and baseline function, which may inform the clinical interpretation of oscillometry.Keywords
Funding Information
- National Health and Medical Research Council (457385, 512387, Cooperative Research Centre for Asthma and Airways)
This publication has 41 references indexed in Scilit:
- Lung Hyperinflation and Its Reversibility in Patients with Airway Obstruction of Varying SeverityCOPD: Journal of Chronic Obstructive Pulmonary Disease, 2010
- Reference equations for respiratory system resistance and reactance in adultsRespiratory Physiology & Neurobiology, 2010
- Expression of bronchodilator response using forced oscillation technique measurements: absoluteversusrelativeEuropean Respiratory Journal, 2010
- Effect of bronchodilation on expiratory flow limitation and resting lung mechanics in COPDEuropean Respiratory Journal, 2009
- The use of plethysmography and oscillometry to compare long‐acting bronchodilators in patients with COPDBritish Journal of Clinical Pharmacology, 2007
- International variation in the prevalence of COPD (The BOLD Study): a population-based prevalence studyThe Lancet, 2007
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- Detection of expiratory flow limitation in COPD using the forced oscillation techniqueEuropean Respiratory Journal, 2004
- Bronchodilator reversibility testing in chronic obstructive pulmonary diseaseThorax, 2003
- Airway re-narrowing following deep inspiration in asthmatic and nonasthmatic subjectsEuropean Respiratory Journal, 2003