Soft contact lens wear in Hong Kong‐Chinese: predicting success*
Authors:
- 1 November 2000
- journal article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 20 (6) , 480-486
Abstract
Summary: The tear stability and tear volume of 55 asymptomatic Hong Kong‐Chinese were assessed before soft contact lens (Hydron Zero 6) wear and repeated on three visits over 28 weeks of lens wear. Soft lens wear caused a significant initial transient decrease in the non‐invasive tear break‐up time (NITBUT), but no change in tear volume as assessed by the self‐prepared cotton thread test (SP‐CTT) and phenol red thread (PRT) test. After 28 weeks, the subjects were classified according to the length of time they could wear their lenses without dry eye related signs and symptoms. The NITBUT and PRT tests were unable to predict the success of soft contact lens wear. However, the SP‐CTT gave a sensitivity and specificity of 88.5 and 52.4%, respectively, in the prediction of subjects most likely to be successful wearers. The positive and negative predictive values at the chosen cut‐off point were 69.7 and 78.6%, respectively. Wetting values, that is, combinations of NITBUT and SP‐CTT values or NITBUT and PRT values, did not predict success in soft contact lens wear.Keywords
This publication has 25 references indexed in Scilit:
- Evaluation of a self-prepared cotton thread test (SP-CTT) and the phenol red thread (PRT) testContact Lens and Anterior Eye, 1998
- The effect of benoxinate on the tear stability of Hong Kong-ChineseOphthalmic and Physiological Optics, 1995
- Inter‐ and intra‐individual variability of non‐invasive tear break‐up time in Hong Kong ChineseClinical and Experimental Optometry, 1994
- Reliability of a Portable Noninvasive Tear Break-Up Time Test on Hong Kong-ChineseOptometry and Vision Science, 1993
- The Cotton Thread Test: A Brief Review and a Clinical Study of Its Reliability on Hong Kong-ChineseOptometry and Vision Science, 1993
- Mechanism of Tear Film Rupture and Its Implications for Contact Lens ToleranceOptometry and Vision Science, 1985
- Effects of Fluorescein on Tear Breakup Time and on Tear Thinning TimeOptometry and Vision Science, 1985
- Tear Film Physiology and Contact Lens Wear. II. Contact Lens-Tear Film InteractionOptometry and Vision Science, 1981
- Schirmer Test After Topical Anesthesia and the Tear Meniscus Height in Normal EyesArchives of Ophthalmology (1950), 1979
- Evaluation of the Schirmer Tear TestSouthern Medical Journal, 1970