Simplification and cost reduction of visual corona tests
Open Access
- 12 January 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (4) , 834-841
Abstract
Visual corona tests are useful to identify the critical corona points of different high‐voltage components. Radio interference voltage and partial discharge measurements also allow detecting corona activity. However, these techniques require expensive screened laboratories, sophisticated instrumentation and usually do not provide the exact location of the discharges. Corona tests are often performed in external laboratories, where customers habitually have to face long waiting times. The tests in such laboratories must be totally planned beforehand, as they are habitually done by external engineers, so little information about the behaviour and possible modifications of the product is acquired by the customer. This study proposes a feasible solution to perform routine corona tests, while greatly reducing the voltage applied, laboratory size and requirements, testing times, and thus test costs. This study also detects the visual corona onset by means of a commercial digital camera, which allows locating the critical corona points, thus greatly decreasing the costs of the corona instrumentation, while maintaining the accuracy and sensitivity of the detection method. The methodology proposed in this study can be applied to many other high‐voltage devices such as conductors, vibration dumpers, corona protections and different types of hardware and fittings for power lines and substations.Keywords
Funding Information
- Agència de Gestió d'Ajuts Universitaris i de Recerca (SGR 2014‐101)
- Ministerio de Economía, Industria y Competitividad, Gobierno de España (RTC‐2014‐2862‐3)
This publication has 21 references indexed in Scilit:
- Positive dc corona inception on dielectric‐coated stranded conductors in airIET Science, Measurement & Technology, 2016
- Modelling of the corona characteristics under damped oscillation impulsesIET Generation, Transmission & Distribution, 2016
- Prediction study on positive DC corona onset voltage of rod‐plane air gaps and its application to the design of valve hall fittingsIET Generation, Transmission & Distribution, 2016
- Accurate measurement of original current pulses because of positive corona in the coaxial cylindrical arrangementIET Science, Measurement & Technology, 2015
- Modelling of corona discharge of a tri‐electrode system for electrostatic separation processesIET Science, Measurement & Technology, 2014
- Comparison of methods for determining corona inception voltages of transmission line conductorsJournal of Electrostatics, 2013
- Determination of the corona inception voltage in an extra high voltage substation connectorIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Numerical calculation of the negative onset corona voltage of high-voltage direct current bare overhead transmission conductorsIET Generation, Transmission & Distribution, 2010
- Inception voltage of corona in bipolar ionized fields-effect on corona power lossIEEE Transactions on Industry Applications, 1998
- Digital analysis of partial dischargesIEEE Transactions on Dielectrics and Electrical Insulation, 1995