Preoperative Radiographic Factors and Surgeon Experience Are Associated With Cortical Breach of C2 Pedicle Screws
Authors:
- Scott L. ParkerSPScott L. Parker
- Matthew J. McGirtMMMatthew J. McGirt
- Ziya L. GokaslanZGZiya L. Gokaslan
- Timothy F. WithamTWTimothy F. Witham
- Ali BydonABAli Bydon
- Jean-Paul WolinskyJWJean-Paul Wolinsky
- Daniel M. SciubbaDSDaniel M. Sciubba
- 1 February 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 23 (1) , 9-14
Abstract
A retrospective review study. In this study, we attempt to identify radiographic variables associated with likelihood of intraoperative breach during C2 pedicle screw placement. In addition, we attempt to correlate surgeon experience with breach rate. Pedicle screws have emerged as an effective approach for obtaining fixation of the axis, yet placement of C2 pedicle screws is technically demanding and poses the risk of injury to the vertebral artery. Given the evidence for substantial variation in C2 anatomy, preoperative assessment of computed tomography (CT) scans may indicate, which patients are at increased risk for cortical breach during the pedicle screw placement. A retrospective review of all patients undergoing C2 pedicle screw fixation at a single institution over the last 6 years was conducted. Radiographic cortical breaches were defined on postoperative CT scans as visualization of the screw beyond the cortical edge. Radiographic measurements were determined from preoperative CT scans and were then correlated with breaches via Student t test. The association of breach rate with surgeon experience was evaluated using univariate linear regression. Ninety-three patients underwent placement of 170 screws. Cortical breach was detected on postoperative CT scans in 43 screws (25.3%). One clinically significant breach occurred with damage to the left vertebral artery intraoperatively. On axial CT sections, mean pedicle isthmus diameter was significantly smaller in patients with breach than in patients without breach for both left and right sides, P=0.006 and P=0.010, respectively. Specifically, a diameter of less than 6 mm was associated with a nearly 2-fold increase in risk of cortical breach (37% vs. 21%). Surgeons with greater experience in placing C2 pedicle screws were noted to have a lower breach incidence (P=0.004). During placement of C2 pedicle screws, likelihood of cortical breach may be associated with size of pedicle and surgeon experience. Extensive preoperative evaluation of CT scans and consideration of technical demands of procedure may help avoid complications with such internal fixation.Keywords
This publication has 26 references indexed in Scilit:
- Laminar screw fixation of the axisJournal of Neurosurgery: Spine, 2008
- Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structures at riskEuropean Spine Journal, 2008
- Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literatureEuropean Spine Journal, 2008
- Comparison of the Anatomical Risk for Vertebral Artery Injury Associated With the C2-Pedicle Screw and Atlantoaxial Transarticular ScrewSpine, 2006
- Computerized Tomographic Measurement of the Cervical Pedicles Diameter in a Malaysian Population and the Feasibility for Transpedicular FixationSpine, 2006
- Posterior C2 Fixation Using Bilateral, Crossing C2 Laminar ScrewsJournal of Spinal Disorders, 2004
- Cervical Pedicle ScrewsSpine, 2000
- Placement of Pedicle Screws in the Human Cadaveric Cervical SpineSpine, 2000
- Primary Posterior Fusion C1/2 in Odontoid FracturesJournal of Spinal Disorders, 1992
- Biomechanical Evaluation of Four Different Posterior Atlantoaxial Fixation TechniquesSpine, 1992