Left ventricular unloading with intra‐aortic counter pulsation prior to reperfusion reduces myocardial release of endothelin‐1 and decreases infarction size in a porcine ischemia‐reperfusion model
Authors:
- Sophie TamareilleSTSophie Tamareille
- Patty R. FelliPFPatty R. Felli
- James AmirianJAJames Amirian
- Richard W. SmallingRSRichard W. Smalling
- 23 July 2008
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (4) , 513-521
Abstract
Objectives: We tested the hypothesis that unloading the left ventricle with intra‐aortic balloon counter‐pulsation just prior to reperfusion provides infarct salvage compared with left ventricular (LV) unloading postreperfusion or reperfusion alone.Background: Previous reports demonstrated infarct salvage with complete LV unloading with an LVAD prior to reperfusion; however, partial LV unloading using intra‐aortic balloon pumps (IABPs) has not been evaluated.Methods: Twenty‐eight Yorkshire pigs were subjected to 1 hr of left anterior descending artery occlusion and 4 hr of reperfusion. An IABP was inserted and activated just prior to reperfusion (IABP‐Pre), or 15 min after reperfusion (IABP‐Post), or not at all (control).Results: At baseline, the hemodynamic data were similar in the three groups. Myocardial infarct size expressed a percentage of zone at risk in control animals was 44.9% ± 4.8%, IAPB‐Pre group 20.9% ± 5.1% (P < 0.05 compared to control), and IABP‐Post group 33.2 ± 6.1% (P = 0.16 vs. control group). There was a correlation between transcardiac endothelin‐1 release at 15 min postreperfusion and infarct size (r = 0.59).Conclusion: LV unloading with an IABP prior to reperfusion reduces the extent of myocardial necrosis in hearts subjected to 1 hr of left anterior descending artery occlusion and 4 hr of reperfusion compared with either reperfusion alone or LV unloading after reperfusion. Inhibition of myocardial ET‐1 release by LV unloading may be a significant mechanism of myocardial protection. These data suggest that in high‐risk STEMI patients, IABP unloading prior to reperfusion might be more beneficial than IABP placement postreperfusion.Keywords
This publication has 26 references indexed in Scilit:
- Deloading of the Left Ventricle by Ventricular Assist Device Normalizes Increased Expression of Endothelin ETA Receptors But Not Endothelin-Converting Enzyme-1 in Patients With End-Stage Heart FailureCirculation, 2000
- Intraaortic Balloon Pumping as Adjunctive Therapy to Rescue Coronary Angioplasty After Failed Thrombolysis in Anterior Wall Acute Myocardial InfarctionThe American Journal of Cardiology, 1995
- Protective effects of non-peptide endothelin receptor antagonist bosentan on myocardial ischaemic and reperfusion injury in the pigCardiovascular Research, 1995
- Increased In Vivo Expression and Production of Endothelin-1 by Porcine Cardiomyocytes Subjected to IschemiaCirculation Research, 1995
- Potential of selective sodium-hydrogen exchange inhibitors in cardiovascular therapyCardiovascular Research, 1995
- Use of aortic counterpulsation to improve sustained coronary artery patency during acute myocardial infarction. Results of a randomized trial. The Randomized IABP Study Group.Circulation, 1994
- Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model.Circulation, 1992
- Role of intracellular Na+ in Ca2+ overload and depressed recovery of ventricular function of reperfused ischemic rat hearts. Possible involvement of H+-Na+ and Na+-Ca2+ exchange.Circulation Research, 1989
- Reducation of the Utilization of the Heart by Left Heart BypassCirculation Research, 1962
- Oxygen Uptake of the Nonworking Left VentricleCirculation Research, 1958