Abstract
We develop a new variant of the factorization method that can be used to detect inclusions in electrical impedance tomography from either absolute current-to-voltage measurements at a single, nonzero frequency or from frequency-difference measurements. This eliminates the need for numerically simulated reference measurements at an inclusion-free body and thus greatly improves the method's robustness against forward modeling errors, e.g., in the assumed body's shape.

This publication has 31 references indexed in Scilit: