Vibrating interventional device detection using real-time 3-D color Doppler
- 3 June 2008
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (6) , 1355-1362
Abstract
Ultrasound image guidance of interventional devices during minimally invasive surgery provides the clinician with improved soft tissue contrast while reducing ionizing radiation exposure. One problem with ultrasound image guidance is poor visualization of the device tip during the clinical procedure. We have described previously guidance of several interventional devices using a real-time 3-D (RT3-D) ultrasound system with 3-D color Doppler combined with the ColorMark technology. We then developed an analytical model for a vibrating needle to maximize the tip vibrations and improve the reliability and sensitivity of our technique. In this paper, we use the analytical model and improved radiofrequency (RF) and color Doppler filters to detect two different vibrating devices in water tank experiments as well as in an in vivo canine experiment. We performed water tank experiments with four different 3- D transducers: a 5 MHz transesophageal (TEE) probe, a 5 MHz transthoracic (TTE) probe, a 5 MHz intracardiac catheter (ICE) transducer, and a 2.5 MHz commercial TTE probe. Each transducer was used to scan an aortic graft suspended in the water tank. An atrial septal puncture needle and an endomyocardial biopsy forceps, each vibrating at 1.3 kHz, were inserted into the vascular graft and were tracked using 3-D color Doppler. Improved RF and wall filters increased the detected color Doppler sensitivity by 14 dB. In three simultaneous planes from the in vivo 3-D scan, we identified both the septal puncture needle and the biopsy forceps within the right atrium using the 2.5 MHz probe. A new display filter was used to suppress the unwanted flash artifact associated with physiological motion.Keywords
This publication has 35 references indexed in Scilit:
- Mitral Valvuloplasty by Inoue Balloon Under Transthoracic Echocardiographic GuidanceJournal of the American Society of Echocardiography, 2005
- In-vitro Visualization of Biopsy Needles with Ultrasound: A Comparative Study of Standard and Echogenic Needles Using an Ultrasound PhantomClinical Radiology, 2001
- Locating a catheter transducer in a three-dimensional ultrasound imaging fieldIEEE Transactions on Biomedical Engineering, 2001
- Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application†Journal of the American Society of Echocardiography, 2001
- An Efficient Algorithm to Remove Low Frequency Doppler Signals in Digital Doppler SystemsUltrasonic Imaging, 1991
- Bias and variance in the estimate of the Doppler frequency induced by a wall motion filterUltrasonic Imaging, 1989
- Endomyocardial biopsy in the United KingdomHeart and Vessels, 1985
- Representations of rapidly oscillating structures on the Doppler displayUltrasound in Medicine & Biology, 1985
- ULTRASONIC IDENTIFICATION OF NEEDLE TIPS IN AMNIOCENTESISThe Lancet, 1984
- Ultrasonic stylets for needles and cathetersUltrasound in Medicine & Biology, 1984