Objective—To determine the effect of pelvic tilt on the Norberg angle (NA) measured in ventrodorsal radiographic views of a hip joint in a canine femoral-pelvic bone model. Sample Population—Radiographic views of a femoral-pelvic bone model with 1 articulated hip joint (without evident laxity). Procedures—The bone model was placed on a radiography table. With the joint fully extended, the pelvic coronal plane was tilted from 0— in 5— increments caudally and cranially to a maximum of 30— in each direction (femoral frontal plane was maintained parallel with the radiograph cassette); a digital ventrodorsal radiographic view was obtained at each tilt position. In each image, the NA was measured 3 times by 2 observers (operators). The effect of pelvic tilt on the NA was evaluated by use of a repeated-measures analysis; within-and between-operator variances were also assessed. Results—Within-operator repeatability was excellent for assessments of hip joint NAs in radiographic views obtained when cranial or caudal tilt was applied to the femoral-pelvic model; replicate measurement variation was < 2.5% (coefficient of variation < 5%). Mean NA values determined by the 2 operators in cranial or caudal tilt views did not differ. Mean between-operator difference in caudal tilt measurements was —0.55— (95% confidence interval, —1.69— to 0.59—) and in cranial tilt measurements was —0.13— (95% confidence interval, —1.33— to 1.06—). Cranial or caudal pelvic tilt did not affect measurement of the NA. Conclusions and Clinical Relevance—Model-derived results indicated that pelvic tilt during acquisition of ventrodorsal radiographic views of the hip joints of a dog should not affect measurement of the NA.Keywords
This publication has 14 references indexed in Scilit:
- Comparison of conventional and digital measurements of tibial plateau angle in dogsJournal of the American Veterinary Medical Association, 2009
- Canine hip dysplasia radiographic screening. Prevalence of rotation of the pelvis along its length axis in 7,012 conventional hip extended radiographsVeterinary and Comparative Orthopaedics and Traumatology, 2007
- EFFECTS OF PELVIC POSITIONING AND SIMULATED DORSAL ACETABULAR RIM REMODELING ON THE RADIOGRAPHIC SHAPE OF THE DORSAL ACETABULAR EDGEVeterinary Radiology & Ultrasound, 2006
- RADIOGRAPHIC AND COMPUTED TOMOGRAPHIC DETERMINATION OF FEMORAL VARUS AND TORSION IN THE DOGVeterinary Radiology & Ultrasound, 2006
- Evaluation of the Norberg Angle Threshold: A Comparison of Norberg Angle and Distraction Index as Measures of Coxofemoral Degenerative Joint Disease Susceptibility in Seven Breeds of DogsVeterinary Surgery, 2006
- Influence of Limb Positioning and Measurement Method on the Magnitude of the Tibial Plateau AngleVeterinary Surgery, 2004
- Evaluation of multiple radiographic predictors of cartilage lesions in the hip joints of eight-month-old dogsAmerican Journal of Veterinary Research, 2003
- The Effects of Femur and Implant Position on the Radiographic Assessment of Total Hip Femoral Implants in DogsVeterinary Surgery, 2002
- Radiographic Evaluation of Acetabular Component Position in DogsVeterinary Surgery, 2001
- Early detection of canine hip dysplasia: comparison of two palpation and five radiographic methodsJournal of the American Animal Hospital Association, 1998