Numerical optimization of three-cavity magneto mercury reciprocating (MMR) micropump
Open Access
- 1 January 2021
- journal article
- research article
- Published by Taylor & Francis in Engineering Applications of Computational Fluid Mechanics
- Vol. 15 (1) , 1954-1966
Abstract
The operation of the three-cavity magneto mercury reciprocating (MMR) micropump, whose prototype were presented in an earlier companion paper, was numerically explored. In the three-cavity MMR micropump, three mercury slugs are moved by a periodic Lorentz force with a phase difference in three separate cavities. A consecutive motion of the slugs in their cavities transfer air from the inlet to the outlet. Two-dimensional OpenFOAM simulations were carried out to explore the influence of electric current excitation phase difference and back-pressure. The numerical simulations predicted the MMR micropump (with no valve) with a phase difference of and produces a mean pumping flow rate of 2.7 and 6.1 mL/min at a back-pressure of 10 Pa and maintains a maximum back-pressure of 17.8 and 20 Pa, respectively. However, it was found that there was a reverse flow at large back-pressures with an excitation phase difference of . The numerical results showed that employing a diffuser/nozzle valve with a length of 5 mm and an angle of improves the mean flow rate of the micropump with a phase difference of at a back-pressure of 10 Pa by 140% from 2.7 to 6.5 mL/min, and its maximum back-pressure by 125% from 17.8 to 40 Pa.
Keywords
This publication has 38 references indexed in Scilit:
- Planar diffuser/nozzle micropumps with extremely thin polyimide diaphragmsSensors and Actuators A: Physical, 2011
- MEMS-based micropumps in drug delivery and biomedical applicationsSensors and Actuators B: Chemical, 2008
- Recent advances in microscale pumping technologies: a review and evaluationMicrofluidics and Nanofluidics, 2008
- Study on a piezoelectric micropump for the controlled drug delivery systemMicrofluidics and Nanofluidics, 2006
- Simulation of two-dimensional fully developed laminar flow for a magneto-hydrodynamic (MHD) pumpBiosensors and Bioelectronics, 2004
- A review of micropumpsJournal of Micromechanics and Microengineering, 2004
- LIGA fabrication and test of a DC type magnetohydrodynamic (MHD) micropumpMicrosystem Technologies, 2000
- An AC magnetohydrodynamic micropumpSensors and Actuators B: Chemical, 2000
- Theoretical and experimental study of MHD (magnetohydrodynamic) micropumpSensors and Actuators A: Physical, 2000
- XV. Experimental researches in electro-magnetism and magneto-electricityPhilosophical Transactions of the Royal Society of London, 1833