Measurement of the acceptance by means of transverse beam excitation with noise
Authors:
- S. SorgeSSS. Sorge
- G. FranchettiGFG. Franchetti
- A. ParfenovaAPA. Parfenova
Open Access
- 31 May 2011
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 14 (5)
Abstract
In this work, we present a technique to measure the acceptance of a circular accelerator extending a previous method by the measurement of particle loss. Here, we apply an rf voltage to transversely excite a coasting heavy ion beam in the SIS-18 synchrotron at GSI. The resulting growth of the transverse beam width causes particle loss when the beam width exceeds the limiting aperture. The acceptance is determined from the measured time evolution of the beam current after particles start to hit the aperture. In doing so, the result will not depend on the initial width of the ion beam.Keywords
This publication has 4 references indexed in Scilit:
- Charge change-induced beam losses under dynamic vacuum conditions in ring acceleratorsNew Journal of Physics, 2006
- The FAIR accelerator project at GSINuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- A theory of the beam loss-induced vacuum instability applied to the heavy-ion synchrotron SIS18Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- An Introduction to the Physics of High Energy Accelerators1993