Familiarization and Reliability of the Isometric Knee Extension Test for Rapid Force Production Assessment
Open Access
- 29 June 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (13) , 4499
Abstract
Despite the rising interest in the use of portable force sensors during isometric exercises to inform on neuromuscular performance, the design of practical field-based methods to obtain reliable measures is an ongoing challenge. We aim at identifying the intra-session and test-retest reliability of a rapid, isometric knee extension test to evaluate the maximal voluntary concentric force (MVC), rate of force development (RFD) and impulse following a field-based approach. On two occasions, 14 athletes unfamiliar with the test completed three sets of 2 s ballistic contractions (as fast and hard as possible) with 30 s rest. Raw and filtered data were collected in real time using a portable force sensor. RFD and impulse were highly reliability during “late” phases of the contraction (0–250 ms) since the first session (coefficient of variation (CV) < 9.8%). Earlier phases (0–150 ms) achieved a moderate reliability after one familiarization session (CV < 7.1%). Measures at 0–50 ms did not reach sufficient reliability (CV~14%). MVC was accurately assessed. Dominant limbs were not importantly altered by the familiarization. In opposite, non-dominant limbs showed large variations. New evidence is provided about the positive effects of a single familiarization session to improve the reliability the isometric knee extension test for rapid force production assessment. Coaches and practitioners may benefit of from these findings to conduct practical and reliable assessments of the rapid force production using a portable force sensor and a field-based approach.Keywords
This publication has 30 references indexed in Scilit:
- Maximal discharge rate of motor units determines the maximal rate of force development during ballistic contractions in humanFrontiers in Human Neuroscience, 2014
- Calculating and reporting effect sizes to facilitate cumulative science: a practical primer for t-tests and ANOVAsFrontiers in Psychology, 2013
- Reliability of neuromuscular measurements during explosive isometric contractions, with special reference to electromyography normalization techniquesMuscle & Nerve, 2012
- Neuromuscular Performance of Explosive Power Athletes versus Untrained IndividualsMedicine & Science in Sports & Exercise, 2010
- Asymmetry in Quadriceps Rate of Force Development as a Functional Outcome Measure in TKAClinical Orthopaedics and Related Research, 2010
- Functional Performance, Maximal Strength, and Power Characteristics in Isometric and Dynamic Actions of Lower Extremities in Soccer PlayersJournal of Strength & Conditioning Research, 2009
- Fast Unilateral Isometric Knee Extension Torque Development and Bilateral Jump HeightMedicine & Science in Sports & Exercise, 2006
- Quadriceps femoris muscle voluntary isometric force production and relaxation characteristics before and 6 months after unilateral total knee arthroplasty in womenKnee Surgery, Sports Traumatology, Arthroscopy, 2006
- Muscle performance during maximal isometric and dynamic contractions is influenced by the stiffness of the tendinous structuresJournal of Applied Physiology, 2005
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998