Abstract
Fatigue crack propagation (FCP) and fatigue lifetime tests have been performed on several types of adhesively bonded aluminum alloy laminates. The laminate systems included several varieties of all-7075-T6(51) laminates--having 2, 4, 8 or 22 layers--as well as bi-material laminates combining 7075-T6 and 2024-T351 alloys. Among the conclusions of the study are: --FCP rates in crack divider laminates for which all layers are the same are comparable to those in the monolithic alloy. --FCP rates in bi-material 7075-T6/2024-T351 laminates are intermediate between those for the two alloys in monolithic form; over a considerable range of growth rates the bi-material laminates give FCP rates significantly lower than the averages of the two constituents. --Fatigue life-times of 7075-T6 8- and 22-layer laminates tested in tension-tension fatigue (R=0.1) are inferior to monolithic 7075-T6 alloy in either notched or unnotched forms; this is contrary to previous results for reversed bending.