Autotransfusion-bacterial contamination during hip arthroplasty and efficacy of cefuroxime prophylaxis: A randomized controlled study of 40 patients
Authors:
Open Access
- 1 January 1997
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 68 (3) , 225-230
Abstract
40 patients undergoing primary hip arthroplasty, given autologous processed blood transfusion, were randomized to receive no antibiotic prophylaxis (group A, n 20) or cefuroxime (1.5 g single injection; group B, n 20). Bacterial contamination at various steps in the autotransfusion procedure was assessed in liquid and solid culture media. the operation field and the wound drainage blood were never contaminated in either of the groups but some of the suction tips were. Parts of the Vacufix® blood collection bags of group A contained bacteria, but none in group B. Processed red blood cell concentrates in both groups showed bacterial growth. Greater blood loss did not increase the contamination rate in general. Isolated bacteria included the species Staphylococcus epidermidis, coagulase-negative staphylococci and Propionibacteria in both groups, but with different cell counts. in addition, Corynebacterium bovis et minutissimum and Moraxella were identified in group A. In conclusion, autologous blood transfusion was a safe procedure. If contamination occurred, the bacterial count was low, and the bacteria of low pathogenicity. Antibiotic prophylaxis with cefuroxime reduced this contamination of suction tips and collection bags and limited the transfer of autologous blood products.Keywords
This publication has 9 references indexed in Scilit:
- Closed suction drainage after hip arthroplasty: Prospective study of bacterial contamination in 81 casesActa Orthopaedica, 1993
- Coagulopathy and Intraoperative Blood Salvage (IBS)1992
- Blood loss and replacement in total hip arthroplasty: a multicenter study. The Preoperative Autologous Blood Donation Study GroupTransfusion, 1992
- Bacterial growth on suction drain tips: Prospective study of 489 clean orthopedic operationsActa Orthopaedica, 1991
- Intraoperative autotransfusion in primary hip arthroplasty: A randomized comparison with homologous bloodActa Orthopaedica, 1991
- Clinical Evaluation of Autotransfusion During Liver TransplantationAnesthesia & Analgesia, 1991
- Incidence of Cell-Saver contamination during cardiopulmonary bypassThe Annals of Thoracic Surgery, 1989
- Autotransfusion of Blood Contaminated by Enteric Contents; A Potentially Life-saving Measure in the Massively Hemorrhaging Trauma Patient?1988
- Emergency Autotransfusion1983