Prospective Randomized Study of Clinical Performance of 3 Aspheric and 2 Spherical Intraocular Lenses in 250 Eyes
Authors:
- Aldo CaporossiACAldo Caporossi
- Gianluca MartoneGMGianluca Martone
- Fabrizio CaspriniFCFabrizio Casprini
- Lorenzo RapisardaLRLorenzo Rapisarda
- 1 September 2007
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 23 (9) , 639-648
Abstract
Purpose: To compare the quality of vision with aspheric and spherical intraocular lenses (IOLs) in pseudophakic patients. Methods: This prospective, comparative, randomized study included 250 eyes of 125 patients with bilateral cataracts. Patients were randomly assigned to receive either IOLs with a spherical biconvex optic (Acrysof SN60AT [Alcon] or Sensar AR40e [Advanced Medical Optics, AMO]) or IOLs with an aspheric optic (Acrysof IQ SN60WF [Alcon], Tecnis Z9000 [AMO], or Sofport L161AO [Bausch & Lomb]). Ophthalmologic examination including best spectacle-corrected visual acuity, pupil size, ocular dominance investigation, contrast sensitivity under mesopic and photopic conditions, and wavefront analysis was performed 2 months postoperatively. Results: Aspheric IOLs showed better contrast sensitivity compared to spherical IOLs at spatial frequencies of 6, 12, and 18 cycles per degree (cpd) under photopic conditions and at all spatial frequencies under mesopic conditions. There was no significant difference among the three aspheric IOLs at all spatial frequencies under either photopic or mesopic conditions. Mean total spherical aberration was statistically lower in dominant eyes with aspheric IOLs (0.05±0.06, 0.11±0.1, and 0.19±0.08 µm for the Tecnis Z9000, Acrysof IQ SN60WF, and Sofport L161AO, respectively) compared with eyes with spherical IOLs (0.62±0.24 and 0.46±0.19 µm for the Acrysof SN60AT and Sensar AR40e, respectively) for a 5-mm pupil diameter. Conclusions: The aspheric IOLs had less wavefront aberrations and performed better under both photopic and mesopic contrast sensitivity compared to the spherical IOLs. These findings confirm it is possible to improve the optical performance of IOLs by modifying the surfaces. [ J Refract Surg. 2007;23:639–648.]Keywords
This publication has 25 references indexed in Scilit:
- Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lensesJournal of Cataract & Refractive Surgery, 2007
- Color perception with AcrySof Natural and AcrySof single-piece intraocular lenses under photopic and mesopic conditionsJournal of Cataract & Refractive Surgery, 2006
- Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameterJournal of Cataract & Refractive Surgery, 2006
- Imaging quality of intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Optical performance of 3 intraocular lens designs in the presence of decentrationJournal of Cataract & Refractive Surgery, 2005
- Glare disability and spherical aberration with five foldable intraocular lenses: a prospective randomized studyActa Ophthalmologica Scandinavica, 2005
- Low contrast visual acuity in pseudophakic patients implanted with an anterior surface modified prolate intraocular lensActa Ophthalmologica Scandinavica, 2004
- Correlation of aberrations with visual acuity and symptomsOphthalmology Clinics of North America, 2004
- Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2003
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994