Abstract
Purpose: Spiral‐based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charactering the base (critically sampled) class of these trajectories.Theory and Methods: Expressions for the gradient waveform, based on slew and amplitude limits, are developed such that a desired pitch in the spiral k‐space trajectory is followed. The source code for this algorithm, written in C, is publicly available. Analytical expressions approximating the spiral trajectory (ignoring the radial component) are given to characterize measurement time, gradient heating, maximum gradient amplitude, and off‐resonance phase for slew‐limited and gradient amplitude‐limited cases. Several numerically calculated trajectories are illustrated, and base Archimedean spirals are compared with analytically obtained results.Results: Several different waveforms illustrate that the desired slew and amplitude limits are reached, as are the desired undersampling patterns, using the numerical method. For base Archimedean spirals, the results of the numerical and analytical approaches are in good agreement.Conclusion: A versatile numerical algorithm was developed, and was written in publicly available code. Approximate analytical formulas are given that help characterize spiral trajectories. Magn Reson Med 71:278–285, 2014.Keywords
Funding Information
- Philips Healthcare
This publication has 14 references indexed in Scilit:
- A new design and rationale for 3D orthogonally oversampled k‐space trajectoriesMagnetic Resonance in Medicine, 2011
- A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectoriesIEEE Transactions on Medical Imaging, 2008
- Design and analysis of a practical 3D cones trajectoryMagnetic Resonance in Medicine, 2006
- Time‐optimal multidimensional gradient waveform design for rapid imagingMagnetic Resonance in Medicine, 2003
- Simple but Reliable Solutions for Spiral MRI Gradient DesignJournal of Magnetic Resonance, 1999
- Simple analytic spiral K-space algorithmMagnetic Resonance in Medicine, 1999
- Fast Spiral Magnetic Resonance Imaging with Trapezoidal GradientsJournal of Magnetic Resonance, 1997
- Improved 2D time-of-flight angiography using a radial-linek-space acquisitionMagnetic Resonance in Medicine, 1997
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Fast Spiral Coronary Artery ImagingMagnetic Resonance in Medicine, 1992