Study of a Chemically Amplified Resist for X-Ray Lithography by Fourier Transform Infrared Spectroscopy
- 1 November 2004
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (11) , 1288-1294
Abstract
Future applications of microelectromechanical systems (MEMS) require lithographic performance of very high aspect ratio. Chemically amplified resists (CARs) such as the negative tone commercial SU-8 provide critical advantages in sensitivity, resolution, and process efficiency in deep ultraviolet, electron-beam, and X-ray lithographies (XRLs), which result in a very high aspect ratio. In this investigation, an SU-8 resist was characterized and optimized for X-ray lithographic applications by studying the cross-linking process of the resist under different conditions of resist thickness and X-ray exposure dose. The exposure dose of soft X-ray (SXR) irradiation at the average weighted wavelength of 1.20 nm from a plasma focus device ranges from 100 to 1600 mJ/cm 2 on the resist surface. Resist thickness varies from 3.5 to 15 μm. The cross-linking process of the resist during post-exposure bake (PEB) was accurately monitored using Fourier transform infrared (FT-IR) spectroscopy. The infrared absorption peaks at 862, 914, 972, and 1128 cm −1 in the spectrum of the SU-8 resist were found to be useful indicators for the completion of cross-linking in the resist. Results of the experiments showed that the cross-linking of SU-8 was optimized at the exposure dose of 800 mJ/cm 2 for resist thicknesses of 3.5, 9.5, and 15 μm. PEB temperature was set at 95 °C and time at 3 min. The resist thickness was measured using interference patterns in the FT-IR spectra of the resist. Test structures with an aspect ratio 3:1 on 10 μm thick SU-8 resist film were obtained using scanning electron microscopy (SEM).Keywords
This publication has 15 references indexed in Scilit:
- Resists for next generation lithographyMicroelectronic Engineering, 2002
- SU8 resist for low-cost X-ray patterning of high-resolution, high-aspect-ratio MEMSMicroelectronics Journal, 2002
- SU-8 as resist material for deep X-ray lithographyMicrosystem Technologies, 2001
- Use of SU-8 photoresist for very high aspect ratio x-ray lithographyMicroelectronic Engineering, 2000
- FT-IR Study of the Imidization Process of Photosensitive Polyimide PMDA/ODAApplied Spectroscopy, 1998
- Implication of DC-space-charge-induced velocity spread on gyrotron gun performanceIEEE Transactions on Plasma Science, 1998
- A Powerful Soft X-ray Source for X-ray Lithography Based on Plasma FocusingPhysica Scripta, 1998
- High rep rate high performance plasma focus as a powerful radiation sourceIEEE Transactions on Plasma Science, 1998
- Studying the Curing Kinetics of a Diacrylate by Using Infrared SpectroscopyApplied Spectroscopy, 1997
- Highly sensitive resist material for deep X-ray lithographyMicroelectronic Engineering, 1997