The Methodology of Doppler-Derived Central Blood Flow Measurements in Newborn Infants
Open Access
- 16 January 2012
- journal article
- review article
- Published by Hindawi Limited in International Journal of Pediatrics
- Vol. 2012, 1-13
Abstract
Central blood flow (CBF) measurements are measurements in and around the heart. It incorporates cardiac output, but also measurements of cardiac input and assessment of intra- and extracardiac shunts. CBF can be measured in the central circulation as right or left ventricular output (RVO or LVO) and/or as cardiac input measured at the superior vena cava (SVC flow). Assessment of shunts incorporates evaluation of the ductus arteriosus and the foramen ovale. This paper describes the methodology of CBF measurements in newborn infants. It provides a brief overview of the evolution of Doppler ultrasound blood flow measurements, basic principles of Doppler ultrasound, and an overview of all used methodology in the literature. A general guide for interpretation and normal values with suggested cutoffs of CBFs are provided for clinical use.Keywords
This publication has 74 references indexed in Scilit:
- Randomized Trial of Milrinone Versus Placebo for Prevention of Low Systemic Blood Flow in Very Preterm InfantsThe Journal of Pediatrics, 2009
- Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilationThe Journal of Pediatrics, 1995
- Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes.Archives of Disease in Childhood - Fetal and Neonatal Edition, 1995
- Early changes in the neonatal circulatory transitionThe Journal of Pediatrics, 1993
- Changes in left ventricular output from fetal to early neonatal lifeThe Journal of Pediatrics, 1991
- Atrial septal defects in neonates with reference to spontaneous closureAmerican Heart Journal, 1988
- A pulsed Doppler echocardiographic study of the postnatal changes in pulmonary artery and ascending aortic flow in normal term newborn infantsAmerican Heart Journal, 1987
- The effect of patent ductus arteriosus on flow velocity in the anterior cerebral arteries: Ductal steal in the premature newborn infantThe Journal of Pediatrics, 1981
- Report of the American Society of Echocardiography Committee on Nomenclature and Standards in Two-dimensional Echocardiography.Circulation, 1980
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978