Diagnostic performance of the Hightop Rapid Diagnostic Test for the detection of anti- Treponema pallidum antibodies in Cameroon: a laboratory-based cross-sectional and comparative study
Open Access
Abstract
Objective: The study was conducted to assess the diagnostic performance of the Hightop Syphilis Rapid Diagnostic Test (RDT) in comparison with the ELISA test used as a reference method. Design: A laboratory-based cross-sectional and comparative study was conducted to assess the diagnostic performance of the Hightop Syphilis RDT. Setting: Blood samples obtained from adult participants in eight health facilities were analysed at the National Public Health Laboratory (NPHL), Ministry of Public Health, Yaounde, Cameroon. Participants: From 29 April to 25 August 2023, 583 adult participants of both sexes (aged ≥21 years), including both syphilis positive and syphilis negative, were recruited consecutively in eight health facilities in eight regions of Cameroon. Outcome measures: Blood samples were screened for the detection of anti-Treponema pallidum antibodies using the One Step Rapid Test (Qingdao Hightop Biotech), a non-treponemal test and ELISA (Biorex Diagnostics, UK), a treponemal test used as a reference method. Diagnostic performance of the Syphilis RDT was analysed using Epi Info V.7 and validated through online statistical tools such as StatPages, GraphPad, QuickCalcs and MedCalc software. Results: Of the 583 samples tested, the Hightop Syphilis RDT revealed a sensitivity of 84.6% (95% CI: 74.8% to 91.1%) and specificity of 98.5% (95% CI: 97.5% to 99.1%). The positive predictive value (PPV) and negative predictive value (NPV) were 84.6% (95% CI: 74.8% to 91.1%) and 98.5% (95% CI: 97.5% to 99.1%), respectively. Regarding the stratification of diagnostic performance by clinical stage, the test showed a sensitivity of 100.0% (95% CI: 71.51% to 100.0%) and specificity of 99.06% (95% CI: 94.86% to 99.98%). The PPV and NPV were 91.67% (95% CI: 61.00% to 98.72%) and 100.0% (95% CI: 96.55% to 100.0%), respectively, in symptomatic individuals. Among asymptomatic individuals, sensitivity was 97.56% (95% CI: 87.14% to 99.94%) and specificity was 100.0% (95% CI: 99.14% to 100.0%). The PPV and NPV were 100.0% (95% CI: 91.19% to 100.0%) and 99.77% (95% CI: 98.40% to 99.97%), respectively. Conclusions: The Hightop Syphilis RDT demonstrated adequate diagnostic performance, particularly among symptomatic individuals, supporting its utility as a reliable tool for syphilis detection in clinical settings.Keywords
This publication has 20 references indexed in Scilit:
- Sensitivity and specificity of a syphilis rapid diagnostic test in blood donors’ samplesThe Brazilian Journal of Infectious Diseases, 2023
- Improved rapid diagnostic tests to detect syphilis and yaws: a systematic review and meta-analysisSexually Transmitted Infections, 2022
- Enzyme‐linked immunosorbent assay (ELISA) versus Venereal Disease Research Laboratory test (VDRL) and rapid plasma reagin test (RPR) for screening of syphilis in pregnant womenInternational Journal of Gynecology & Obstetrics, 2020
- Three-dimensional Epigenome Statistical Model: Genome-wide Chromatin Looping PredictionScientific Reports, 2018
- SyphilisNature Reviews Disease Primers, 2017
- SyphilisThe Lancet, 2017
- SyphilisDisease-a-Month, 2016
- Prevention and treatment of mother-to-child transmission of syphilisCurrent Opinion in Infectious Diseases, 2016
- The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional studyBMJ Open, 2015
- Serologic Testing for Syphilis: Benefits and Challenges of a Reverse AlgorithmClinical Microbiology Newsletter, 2014