Optimization of Cardiac Resynchronization Therapy: Comparison of Acoustic Cardiography and Echocardiographic Methods for Optimizing the Implanted Cardiac System
Open Access
- 1 January 2025
- journal article
- Published by Wolters Kluwer Health in International Journal of Heart Rhythm
- Vol. 10 (1) , 1-5
Abstract
Background: Optimization of the resynchronization system is one of the few elements determining a patient’s response to the implantation of cardiac resynchronization therapy (CRT). The aim of this study was to compare two optimization methods of the implanted resynchronization system—acoustic cardiography performed by means of cardiac acoustic sensors and echocardiographic cardiography—and to demonstrate that acoustic cardiography is not worse than the previously used echocardiographic method. Subjects and Methods: This study involved 54 patients (43 males and 11 females) with heart failure who underwent CRT in accordance with the 2010 European Society of Cardiology guidelines. The patients were divided into two groups: one optimized via echocardiography (29 patients) and the other optimized via acoustic cardiography (25 patients). Optimization occurred within 6 months of device implantation. Results: Both cardiac acoustic and echocardiographic methods improved maximum oxygen absorption 3 months after optimization, and there was no significant difference between these two methods. Conclusions: Both methods, audicor and echocardiography, improved CRT. The cardiac acoustic method is not worse than the previously used echocardiographic method.Keywords
This publication has 7 references indexed in Scilit:
- Clinical outcomes with synchronized left ventricular pacing: Analysis of the adaptive CRT trialHeart Rhythm, 2013
- Randomized controlled trial comparing simultaneous versus optimized sequential interventricular stimulation during cardiac resynchronization therapyAmerican Heart Journal, 2012
- The European Cardiac Resynchronization Therapy Survey: Comparison of Outcomes between De Novo Cardiac Resynchronization Therapy Implantations and UpgradesEuropean Journal of Heart Failure, 2011
- Primary Results From the SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy (SMART-AV) TrialCirculation, 2010
- Echocardiography for Cardiac Resynchronization Therapy: Recommendations for Performance and Reporting–A Report from the American Society of Echocardiography Dyssynchrony Writing Group Endorsed by the Heart Rhythm SocietyJournal of the American Society of Echocardiography, 2008
- Comparison of different approaches for optimization of atrioventricular and interventricular delay in biventricular pacingEP Europace, 2008
- Role of echocardiography to determine candidacy for cardiac resynchronization therapyCurrent Opinion in Cardiology, 2008