Final solution in femoroacetabular impingement - Threaded cups in hip revision surgery 2002-2012
Open Access
- 23 October 2018
- journal article
- Published by Heighten Science Publications Corporation in Journal of Sports Medicine and Therapy
- Vol. 3 (4) , 089-095
Abstract
Purpose: Here, we report the complications of endoprosthesis with threaded cups according to our application in cases of complicated acetabulum (hip revisions and femoroacetabular impingement (FAI)). Methods: A total of 504 patients was analyzed, including 189 men and 315 women. For re-implanted patients (n = 49), the mean time to re-implantation was 6.3 years and the average age at re-implantation was 54.7 years. For censored patients (n = 455), the mean time to censoring was 5.5 years and the average age of the implant was 55.7 years. Among the patients that were censored, 77 died and 378 patients did not experience an event necessitating re-implantation. Results: For the total study population, the Kaplan-Meier estimate of 5 year survival is 0.94 and of 10 year survival is 0.85. 90% of the implants survived 7 years, 80% of the implants survived almost 12 years and 70% of implants survived almost 15 years. Kaplan-Meier survival analysis suggests that men have higher survival than women. Age of the patient at the time of implant was not a statistically significant factor for re-implantation (p value = 0.21) but sex was (p value = 0.02). Women had 2.25 times more risk of being re-implanted than men. Conclusions: In our case series, the failure rate, as a result of aseptic loosening, was 7.4% (n = 51). More than half the failure cases (56%) required re-implantation. Over one-third (37%) of the primary arthrosis cases, were found to be FAI, lessening the frequency of diagnosis of the former. In our clinic, the threaded cup seems to be indispensable in hip revision surgery and in treating FAI.Keywords
This publication has 17 references indexed in Scilit:
- Long-Term Outcome of 73 Zweymüller Total Hip Prostheses with a Screw Cup in Patients under 50 Years of AgeHIP International, 2012
- Primary stability of cementless threaded acetabular cups at first implantation and in the case of revision regarding micromotions as indicatorsBiomedical Engineering / Biomedizinische Technik, 2012
- High Hip Center Technique Using a Biconical Threaded Zweymüller® Cup in Osteoarthritis Secondary to Congenital Hip DiseaseClinical Orthopaedics and Related Research, 2010
- Inter- and intra-observer variability of the Crowe and Hartofilakidis classification systems for congenital hip disease in adultsThe Journal of Bone and Joint Surgery. British volume, 2008
- Treatment of High Dislocation of the Hip in Adults with Total Hip Arthroplasty. Operative Technique and Long-Term Clinical Results*Journal of Bone and Joint Surgery, 1998
- Hip replacement with a threaded acetabular cup. A follow-up study.Journal of Bone and Joint Surgery, 1994
- Loosening of threaded acetabular componentsThe Journal of Arthroplasty, 1993
- Threaded acetabular components for primary and revision total hip arthroplastyThe Journal of Arthroplasty, 1990
- Threaded Cup AcetabuloplastyClinical Orthopaedics and Related Research, 1989
- Finite element analysis of acetabular reconstruction: Noncemented threaded cupsActa Orthopaedica, 1987