The Evaluation of a Lateral Flow Strip Based on the Covalently Fixed “End-On” Orientation of an Antibody for Listeria monocytogenes Detection
Open Access
- 15 May 2024
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (21) , 8543-8551
Abstract
In this study, the covalently fixed "end-on" orientation of a monoclonal Listeria monocytogenes antibody (mAb-Lis) to amino terminated oligo (ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) was used to fabricate an in-house lateral flow strip (LFS), namely, the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS. The aim was to evaluate the performance of the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS in detecting L. monocytogenes. The proposed LFS enabled the sensitive detection of L. monocytogenes in 15 min with a visual limit of detection of 102 CFU/mL. Quantitative analysis indicated an LOD at 10 CFU/mL. The fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS showed no cross-reactivity with other pathogenic bacteria and practical performance across different food matrices, including human blood, milk, and mushroom samples. Furthermore, the clinical performance of the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS for detecting L. monocytogenes was evaluated by using 12 clinical samples validated by the hemoculture method. It demonstrated excellent concordance with the reference methods, with no false-positive or false-negative results observed. Therefore, the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS serves as a promising candidate for a point-of-care test (POCT), enabling the rapid, precise, and highly sensitive detection of L. monocytogenes in clinical samples and contaminated food.Keywords
Funding Information
- the NSRF via the Program Management Unit for Human Resources & Institutional Development, Research, and Innovation (PMU-B) (Grant number B01F650006)
- Centre for Research and Development of Medical Diagnostic Laboratories, Faculty of Associated Medical Sciences, Khon Kaen University
This publication has 44 references indexed in Scilit:
- Listeria monocytogenes detection on food contact surfaces: suitability of different swab materialsJournal of Consumer Protection and Food Safety, 2023
- Development of a novel lateral flow immunoassay based on Fe3O4@MIL-100(Fe) for visual detection of Listeria monocytogenesJournal of Food Measurement and Characterization, 2023
- Alternative approaches to the risk management of Listeria monocytogenes in low risk foodsFood Control, 2021
- Green synthesis of salt-tolerant gold nanoparticles for the rapid qualitative detection of Listeria monocytogenes in lateral flow immunoassayJournal of Materials Science, 2020
- Changing epidemiology of Listeria monocytogenes outbreaks, sporadic cases, and recalls globally: A review of ProMED reports from 1996 to 2018International Journal of Infectious Diseases, 2019
- Lateral flow immunoassays combining enrichment and colorimetry-fluorescence quantitative detection of sulfamethazine in milk based on trifunctional magnetic nanobeadsFood Control, 2019
- Nanomaterial-Based Biosensors in Agriculture Application and Accessibility in Rural Smallholding Farms: Food Security2017
- Identification and quantification of eight Listeria monocytogene serotypes from Listeria spp. using a gold nanoparticle-based lateral flow assayMicrochimica Acta, 2016
- A paper-based lateral flow assay for morphineAnalytical and Bioanalytical Chemistry, 2014
- Prevalence of foodborne pathogens in open markets and supermarkets in ThailandFood Control, 2010