Comparison of Postoperative Coronal Leg Alignment in Customized Individually Made and Conventional Total Knee Arthroplasty
Open Access
- 12 June 2021
- journal article
- research article
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (6) , 549
Abstract
Neutral coronal leg alignment is known to be important for postoperative outcome in total knee arthroplasty (TKA). Customized individually made implants (CIM) instrumented with patient-specific cutting guides are an innovation aiming to increase the precision and reliability of implant positioning and reconstruction of leg alignment. We aimed to compare reconstruction of the hip–knee–ankle angle (HKA) of the novel CIM system iTotal™ CR G2 (ConforMIS Inc.) to a matched cohort of the off-the-shelf (OTS) knee replacement system Vanguard™ CR (Zimmer Biomet). Retrospective analysis of postoperative coronal full-leg weight-bearing radiographs of 562 TKA (283 CIM TKA, 279 OTS TKA) was conducted. Via a medical planning software, HKA and rotation of the leg were measured in postoperative radiographs. HKA was then adjusted for rotational error, and 180° ± 3° varus/valgus was defined as the target zone HKA. Corrected postoperative HKA in the CIM group was 179.0° ± 2.8° and 179.2° ± 3.1° in the OTS group (p = 0.34). The rate of outliers, outside of the ±3° target zone, was equal in both groups (32.9%). Our analysis showed that TKA using patient-specific cutting guides and implants and OTS TKA implanted with conventional instrumentation resulted in equally satisfying restoration of the coronal leg alignment with less scattering in the CIM group.Keywords
This publication has 23 references indexed in Scilit:
- Design rationale for customized TKA: a new idea or revisiting the past?Current Reviews in Musculoskeletal Medicine, 2012
- Computer Assistance Increases Precision of Component Placement in Total Knee Arthroplasty with Articular DeformityClinical Orthopaedics and Related Research, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Alignment in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Is there an alternative to the full‐leg radiograph for determining knee joint alignment in osteoarthritis?Arthritis Care & Research, 2006
- Prosthetic alignment and sizing in computer-assisted total knee arthroplastyInternational Orthopaedics, 2004
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Total knee arthroplasty implanted with and without kinematic navigationInternational Orthopaedics, 2003
- Effect of Rotation and Knee Flexion on Radiographic Alignment in Total Knee ArthroplastiesClinical Orthopaedics and Related Research, 1996