A phase shifted full bridge converter with novel control over the leakage inductance
- 27 October 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Abstract
The electronics industry is progressing towards the high density board solutions due to the requirement of compact and intelligent electronic systems. In order to meet the industry demands, the power system is required to be of high power density. This article proposes one of the solution to improve the power density for the medium power applications. In phase shifted full bridge converter, the intrinsic leakage inductance of the main transformer is not high enough to obtain the zero voltage switching of the power switches for the entire operating conditions. An additional shim inductor is usually connected in series with the primary winding of the main transformer to increase the collective leakage inductance. This additional shim inductor degrades the power density of the converter. This paper proposes a method to embed and control the resonance inductance inside the main transformer. In addition to the increased inter-winding spacing, this paper proposes a practical approach to integrate the ferrite rods inside the main transformer for further increase in the leakage inductance. A power transformer is constructed and investigated by using the modelled equations to estimate the leakage inductance. A prototype phase shifted full bridge converter is also developed to investigate the performance of the proposed transformer. The converter is designed for the switching frequency of 400kHz, and tested up to 600watts output power at the input voltage of 200Vdc. The performance of the proposed converter is also compared with the converter of using an external inductor. The investigations show that, in addition to the improved power density, the converter with the proposed transformer is more efficient than the converter with the traditional transformer.Keywords
This publication has 15 references indexed in Scilit:
- An improved modelling and construction of power transformer for controlled leakage inductance2016
- A novel adaptive magnetizing inductance control scheme for high-efficiency LLC resonant converter for PV applications2015
- A Soft-Switched Asymmetric Flying-Capacitor Boost Converter With Synchronous RectificationIEEE Transactions on Power Electronics, 2015
- A phase shifted full bridge converter with ZCS synchronous rectifier for auxiliary power units2014
- Leakage Inductance Calculation for Planar Transformers With a Magnetic ShuntIEEE Transactions on Industry Applications, 2014
- Analytical calculation of resonant inductance for zero voltage switching in phase‐shifted full‐bridge convertersIET Power Electronics, 2013
- Optimized design of medium frequency transformers with high isolation requirements2010
- ZVS phase shift full bridge converter with controlled leakage inductance of transformer2009
- A novel soft-switching full-bridge DC/DC converter: analysis, design considerations, and experimental results at 1.5 kW, 100 kHzIEEE Transactions on Power Electronics, 1991
- Design considerations for high-voltage high-power full-bridge zero-voltage-switched PWM converter1990