Enhanced Performance Test Mix for High-Throughput LC/MS Analysis of Pharmaceutical Compounds
Authors:
- 28 September 2006
- journal article
- Published by American Chemical Society (ACS) in Journal of Combinatorial Chemistry
- Vol. 8 (6) , 820-828
Abstract
LC/MS is being used for the routine analysis of small molecules in both the discovery and development stages within the pharmaceutical industry. In drug discovery, LC/MS is relied upon to confirm the identity and assess the purity of chemical entities. To ensure the quality of LC/MS analysis, it is important that the LC/MS system is operating within defined performance criteria. Performance monitoring of the system with a standard compound mix offers many advantages over other alternatives, since it monitors the LC/MS system as an integrated unit under the same working conditions as those used for the analysis of samples. It is also a convenient approach, because the test mix can be injected as part of the automated sequence. Use of a test mix for similar purposes has been described previously (Tang, L.; Fitch, W. L.; Alexander, M. S.; Dolan, J. W. Anal. Chem.2000, 72, 5211−5218). To monitor the performance of ArQule's LC/MS operation (with UV and ELS detection) in greater detail, a set of eight compounds was selected from a collection of 137 commercially available “druglike” compounds. The compounds are generally stable and compliant with the rule-of-five criteria. This enhanced mix has a balanced selection of pKa values and covers the typical range of hydrophobicity and molecular masses of pharmaceutical compounds. Moreover, the selected compounds can generally be ionized using ESI and APCI modes with positive and negative polarity. The test mix can be used under formic acid or ammonium hydroxide conditions and with methanol or acetonitrile as an organic modifier. Performance monitoring with the enhanced mix is demonstrated with respect to ionization and mass measurement, as well as changes in gradient profile, flow rate, buffer pH, and ionic strength.Keywords
This publication has 31 references indexed in Scilit:
- Toward Single-Calibrant Quantification in HPLC. A Comparison of Three Detection Strategies: Evaporative Light Scattering, Chemiluminescent Nitrogen, and Proton NMRAnalytical Chemistry, 2005
- Column selectivity in reversed-phase liquid chromatographyJournal of Chromatography A, 2005
- The hydrophobic-subtraction model of reversed-phase column selectivityJournal of Chromatography A, 2004
- Comparison of product ion spectra obtained by liquid chromatography/triple‐quadrupole mass spectrometry for library searchRapid Communications in Mass Spectrometry, 2004
- High‐throughput liquid chromatography ultraviolet/mass spectrometric analysis of combinatorial libraries using an eight‐channel multiplexed electrospray time‐of‐flight mass spectrometerRapid Communications in Mass Spectrometry, 2002
- Determination of selected sulfonamide antibiotics and trimethoprim in manure by electrospray and atmospheric pressure chemical ionization tandem mass spectrometryRapid Communications in Mass Spectrometry, 2002
- Tuning compounds for electrospray ionization/in‐source collision‐induced dissociation and mass spectra library searchingJournal of Mass Spectrometry, 2001
- Determination of N-Nitrosodimethylamine at Part-per-Trillion Levels in Drinking Waters and Contaminated GroundwatersAnalytical Chemistry, 1995
- Solvatochromically based solvent-selectivity triangleJournal of Chromatography A, 1993
- Separation of anthocyanin chalcones by high-performance liquid chromatographyJournal of Chromatography A, 1981