Optical measurements of high-frequency pressure fluctuations using a pressure-sensitive paint and Cassegrain optics
Authors:
- 12 September 2002
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 13 (10) , 1591-1598
Abstract
Optical measurements of high-frequency pressure fluctuations have been performed to examine the dynamic response of a fast-responding porous pressure-sensitive paint (PSP). The PSP was composed of meso-tetra(pentafluorophenyl) porphine and a commercial silica-gel thin-layer chromatography plate. Pressure fluctuations at frequencies on the order of kilohertz were produced on a flat plate by chopping an underexpanded air-jet and then measured by using a newly developed, optical pressure measurement system (OPMS) with a Cassegrain-type optical probe. Pressure traces obtained by the present OPMS and their amplitude spectra were compared with those obtained by a piezo-resistive pressure transducer. The present results demonstrate the feasibility of the present OPMS for measuring high-frequency pressure fluctuations with a high spatial resolution and reveal that the present porous PSP can follow pressure fluctuations at frequencies of several kilohertz at least.Keywords
This publication has 14 references indexed in Scilit:
- Time Response of Anodized Aluminum Pressure-Sensitive PaintAIAA Journal, 2001
- Temperature- and Pressure-Sensitive Paint Measurements in Short-Duration Hypersonic FlowAIAA Journal, 2001
- SURFACEPRESSUREMEASUREMENTSUSINGLUMINESCENTCOATINGSAnnual Review of Fluid Mechanics, 2001
- Temperature- and Pressure-Sensitive Luminescent Paints in AerodynamicsApplied Mechanics Reviews, 1997
- Step response of pressure-sensitive paintsAIAA Journal, 1996
- Submillisecond response times of oxygen-quenched luminescent coatingsReview of Scientific Instruments, 1993
- Surface pressure field mapping using luminescent coatingsExperiments in Fluids, 1993
- Aerodynamic applications of pressure sensitive paintAIAA Journal, 1993
- Luminescent barometry in wind tunnelsReview of Scientific Instruments, 1990
- New technique of surface flow visualization based on oxygen quenching of fluorescenceReview of Scientific Instruments, 1980