Biosensor signal improvement using current mirror topology for dissolved oxygen measurement
- 30 April 2019
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (6) , 065102
Abstract
A biosensor system for dissolved oxygen level detection based on a current mirror method has been designed and characterized. Most biosensor systems implement a transimpedance circuit to convert the flowing current on the sensor to an output voltage signal. These systems are voracious and susceptible to instability and noise due to the configuration of the circuit used. The power supply is also impractical due to the bipolar polarity needed, and the systems consume more power since they use more active devices in the op-amp. These disadvantages need to be overcome when special requirements are needed such as low-noise measurement in dissolved oxygen level detection, and for battery-powered and low-power devices for in situ and remote area measurement. Differing from transimpedance, current mirror circuits convert the flowing current to the output voltage by copying the current with a ground-referenced input and output, and use fewer active devices. The proposed current mirror circuit aims to diminish the noise of the output and minimize the power consumption through reducing the active devices used. The results show some significant signal quality improvements when using the current mirror circuit, where the noise response of the current mirror circuit is ten times lower than the transimpedance circuit.Keywords
Funding Information
- Directorate of Research and Community Service, General Directorate of Research Strengthening and Development, Ministry of Research, Technology, and Higher Education of Indonesia (Research Grant 086/SP2H/LT/DRPM/201)
This publication has 17 references indexed in Scilit:
- AN ARDUINO UNO BASED BIOSENSOR FOR WATER POLLUTION MONITORING USING IMMOBILISED ALGAE CHLORELLA VULGARISInternational Journal on Smart Sensing and Intelligent Systems, 2017
- Lab-on-chip with microalgal based biosensor for water assessment2016
- Bioindicators: the natural indicator of environmental pollutionFrontiers in Life Science, 2016
- An Intelligent Optical Dissolved Oxygen Measurement Method Based on a Fluorescent Quenching MechanismSensors, 2015
- Application of algae-biosensor for environmental monitoring2015
- Cancellation of OpAmp Virtual Ground Imperfections by a Negative Conductance Applied to Improve RF Receiver LinearityIEEE Journal of Solid-State Circuits, 2014
- Fibre Optic Sensors for Selected Wastewater CharacteristicsSensors, 2013
- Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical SensorsIEEE Transactions on Circuits and Systems I: Regular Papers, 2008
- Fabrication of miniature Clark oxygen sensor integrated with microstructureSensors and Actuators B: Chemical, 2005
- A 622 Mb/s 4.5 pA/√Hz CMOS transimpedance amplifier [for optical receiver front-end]2002