Diagnostic Catheterization and Balloon Sizing of Atrial Septal Defects by Echocardiography Guidance Without Fluoroscopy
Authors:
- Ingo DaehnertIDIngo Daehnert
- Sven DittrichSDSven Dittrich
- Peter. E LangePLPeter. E Lange
- 1 February 2000
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 17 (2) , 159-163
Abstract
To avoid x‐ray exposure prior to interventional closure of atrial septal defects (ASDs), we recently developed a technique for diagnostic catheterization and balloon sizing of the defect by echocardiography guidance without fluoroscopy. We report on our first experiences with this technique. Fourteen patients with atrial septal perforations (mean age, 23 years; range, 1–66 years) underwent diagnostic catheterization and balloon sizing prior to possible interventional defect closure. Mean size of the defects was 16 mm (7–29 mm). Mean left‐to‐right shunt was Qp/Qs =2.0 (range, 1.0–4.0). Without fluoroscopy, the procedures were performed in two children by transthoracic echocardiography (TTE) and in 12 patients by both TTE and transesophageal echocardiography (TEE). Mean procedure time was 59 minutes (range, 35–90 minutes). We conclude that oxymetry, pressure recordings, and the estimation of the balloon‐stretched size of atrial septal perforations can be performed safely by echocardiographic guidance without fluoroscopy. The x‐ray exposure for patient selection prior to a transcatheter closure of an ASD can be avoided with this technique.Keywords
This publication has 9 references indexed in Scilit:
- Transcatheter closure of atrial septal defects under echocardiographic guidance without X-ray: initial experiences.Cardiology in the Young, 1999
- Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal OccluderCardiology in the Young, 1999
- Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL)Heart, 1998
- Closure of Atrial Septal Defects With the Amplatzer Occlusion Device: Preliminary ResultsJACC, 1998
- Imaging and Sizing of Atrial Septal Defects by Magnetic ResonanceCirculation, 1995
- Seven-Year Experience of Noninvasive Preoperative Diagnostics in Children with Congenital Heart Defects: Comprehensive Analysis of 2,788 Consecutive PatientsCardiology, 1995
- Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusionAmerican Heart Journal, 1992
- Accuracy of doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defectJACC, 1988
- Surgical repair of uncomplicated atrial septal defect without “routine” preoperative cardiac catheterizationJACC, 1985